Flow of a Fluid Contained between Concentric Cylinders Both Rotating
スポンサーリンク
概要
- 論文の詳細を見る
The flow between concentric cylinders both rotating in the same or opposite directions has been studied by flow visualization and velocity measurement. We used slit illumination for flow observation and pitot and hot wire probes for velocity measurement and obtained the following results. When the outer cylinder rotates faster than the inner one in the same direction , the flow is stabilized and the laminar flow region is fairly wide but there is a fluctuation which is too small to observe. The boundary beyond which a spiral turbulence occurs has marked hysteresis and changes with the fluid used. When the tow cylinders rotate in opposite direction s, Taylor vortices and spiral turbulence arise almost simultaneously and both exist together in the gap at some Reynolds number. Such situation is supported by velocity fluctuation and its power spectrum.
- 一般社団法人日本機械学会の論文
著者
-
IMAO Shigeki
Department of Mechanical and Systems Engineering, Gifu University
-
Imao Shigeki
Department Of Mechanical Engineering Nagoya Institute Of Technology
-
Yamada Yutaka
Department Of Animal Production Hokkaido National Agricultural Experiment Station
-
Yamada Yutaka
Department Of Mechanical Engineering Nagoya Institute Of Technology
関連論文
- OJ-140 Statins Reduce No-reflow Phenomenon and Prevent Left Ventricular Remodering after Coronary Reperfusion in Patients with Acute Myocardial Infarction(Acute myocardial infarction, clinical (diagnosis/treatment)-2, The 71st Annual Scientific Meeting of
- Comparisons of the Skeletal Muscle Metabolic Abnormalities in the Arm and Leg Muscles of Patients With Chronic Heart Failure
- Thrombolysis and Aspiration Thrombectomy Additively Improve the Clinical Outcome of PCI in Acute Myocardial Infarction(Acute Myocardial Infarction, Clinical (Diagnosis/Treatment) 11 (IHD), The 69th Annual Scientific Meeting of the Japanese Circulation Soc
- Significance of Reversed Redistribution in Exercise Thallium-201 SPECT Imaging in Patients with Vasospastic Angina
- Hybrid Re-Perfusion Therapy with Coronary Thrombolysis and PCIImproved the Clinical Outcome of Acute Myocardial Infarction (AMI)
- PJ-012 Cardiac MRI detects right ventricular involvement in acute myocardial infarction with right coronary artery culprit(Acute myocardial infarction, clinical(diagnosis/treatment)(08)(IHD),Poster Session(Japanese),The 72nd Annual Scientific Meeting of t
- Temperature Dependence of the Photoluminescence of Porous Silicon
- A CASE OF SUBMANDIBULAR HEMANGIOMA WITH PHLEBOLITH
- Colonic cancer in a patient with primary sclerosing cholangitis and long-standing ulcerative colitis
- Are high barometric pressure, low humidity and diurnal change of temperature related to the onset of asthmatic symptoms?
- Time-course changes of eosinophil counts in premature infants : No effects of medical manipulation, except erythropoietin treatment, on eosinophilia
- Effects of Different Sizes of β-tricalcium Phosphate Particles on Bone Augmentation within a Titanium Cap in Rabbit Calvarium
- A Turbulent Cylindrical Wall Jet Equipped with a Front-Facing Step Impinging Normally on a Flat Plate
- F306 STUDY ON A TURBULENT CYLINDRICAL WALL JET FLOW : FLOW PROPERTIES ON A ROUGH WALL SURFACE(Near-wall turbulence and its control)
- An Experimental Investigation of a Turbulent Cylindrical Wall Jet Equipped with Front-Facing Step : Separation and Reattachment Properties of Wall Jet Flow
- MgB_2超伝導線材における臨界電流の向上
- Prosthodontics for Young People with Partial Anodontia
- Successful control of persistent hyperinsulinemic hypoglycemia of infancy with a high dextrin formula
- NEUTROPHILS OF OVINE PERIPHERAL BLOOD IN ELECTRON MICROSCOPY
- EOSINOPHILS OF OVINE PERIPHERAL BLOOD IN ELECTRON MICROSCOPY
- The Laminar Flow in the Developing Region of a Rotating Pipe
- A Chronological Stability Evaluation of Implanted Structures via Resonance Frequency Analysis
- GnRH Inducing LH Release, Nutrition and Plasma Cortisol in High Producing Dairy Cows Postpartum
- Measurements of Pressure Distribution around Eccentric Cylinders, with the Outer Cylinder Rotating
- Superconducting Properties and Structure of MgB_2 Tapes with SiC Addition Prepared by the Hot Pressing
- Frictional Moment and Pressure Drop of the Flow through Co-Axial Cylinders with an Outer Rotating Cylinder
- THE LEUKOCYTES OF OVINE PERIPHERAL BLOOD IN ELECTRON MICROSCOPY
- Viscous Frictional Moment between Eccentric Rotating Cylinders when Outer Cylinder Rotates
- Pressure Drop Measurements of the Flow through Eccentric Cylinders with Rotating Inner Cylinders
- Thermal Boundary Conductance between Multi-Walled Carbon Nanotubes
- On the Flow between Eccentric Rotating Cylinders when the Outer Cylinder Rotates
- Flow of a Fluid Contained between Concentric Cylinders Both Rotating
- DIFFERENTIAL RELEASE OF ADRENALINE, NORADRENALINE AND DOPAMINE FROM ISOLATED AND PERFUSED ADRENAL GLANDS OF CAT, GUINEA PIG AND GOAT
- On the Facilitation Effect of Neutral Macrocyclic Ligands on the Ion Transfer across the Interface between Aqueous and Organic Solutions. I. Theoretical Equation of Ion-Transfer-Polarographic Current-Potential Curves and Its Experimental Verification.