Dynamic Characteristics of a Bypass Type Flowmeter
スポンサーリンク
概要
- 論文の詳細を見る
Dynamic characteristics of a bypass type flowmeter in pulsating flow and in transient flow were studied analytically and experimentally. (1) Parameters which influence measurement errors of the mean flow rate of pulsating flow with the bypass type flowmeter were clarified. (2) Depending on the configuration of the bypass passage, there were cases where the measured value of mean flow rate was larger than the true value and where it was less; a suitable configuration of the bypass passage should be used, to obtain a value that is close to the true one. (3) Parameters which influence response of the flow in the byapss passage during accelerating or decelerating flow were clarified.
- 一般社団法人日本機械学会の論文
著者
-
Nishimura Yutaka
Hitachi Research Laboratory Hitachi Ltd.
-
Ohyama Yoshishige
Hitachi Car Engineering Co. Ltd.
関連論文
- Characteristics of Ratio Control Systems with a Fuel Control Device Directly Connected to an Air Flow Metering Element : Series C : Vibration, Control Engineering, Engineering for Industry
- A Flow Rate Control Valve Using a Piezoelectric Element
- The Atomization Characteristics of a Vibration-type Atomizer when Fuel is Supplied Intermittently
- A study on the measurement of particle size distribution with laser diffraction systems
- Dust-proof Characteristics of a Bypass Flow Type Flowmeter Using a Hot Wire
- Analysis of Mixture Transport Delay in Fuel Supply for Carbureted Engine
- Dynamic Characteristics of a Bypass Type Flowmeter
- Pulsating Flow Characteristics of Hot-Wire Air Flow Meter for Gasoline Fuel-Injection Systems
- (2-19) Real-Time Engine Control Using a Combustion Model for Lean Boost Engines((SI-6)S. I. Engine Combustion 6-Modeling)