Response of Bayonet-type Heat Exchangers to Sinusoidal Flow Rate Changes of Large Amplitude
スポンサーリンク
概要
- 論文の詳細を見る
A computational method is presented for obtaining the steady-state temperature responses of bayonet-type heat exchangers subject to sinusoidal flow rate changes of large amplitude. The frequency- and amplitude-dependent describing functions between the input sinusoidal flow rate changes and the fundamental component of the steady-state response of the outlet temperature of tube-side of shell-side fluid are also derived. Numerical examples are given and the effects of the amplitude of the flow rate changes on the frequency responses are shown: (1) The vector loci of the describing functions are illustrated. (2) The dc-components of the periodic responses are plotted for various values of the amplitude. Finally the responses calculated by the present method are confirmed by means of the Runge-Kutta-Gill method, and it is shown that the present method can reduce the computation time remarkably.
- 一般社団法人日本機械学会の論文
著者
関連論文
- Response of Multipass Heat Exchangers to Sinusoidal Flow Rate Changes of Large Amplitude
- Response of Bayonet-type Heat Exchangers to Sinusoidal Flow Rate Changes of Large Amplitude
- Dynamic Response of Bayonet-Type Heat Exchangers : Part 1, Response to Inlet Temperature Changes
- Optimum Control Based on an Evaluation Function Including the Initial Investment
- Response of Parallel-flow and Counterflow Heat Exchangers to Sinusoidal Flow Rate Changes of Large Amplitude