A Study on the Measurement of Bubble Size Distribution in the Upward Bubbly Flow
スポンサーリンク
概要
- 論文の詳細を見る
The present report describes a measurement technique for the determination of bubble size distribution in a bubbly flow. Electrical proves with two electrodes A and B located at a distance d_1 in the flow direction, or at right angles to the flow direction are used to detect the void signal A ∩ B when both electrodes A and B touch a bubble. The measurement is carried out in the case of air bubbles being ejected from void generators made of sintered metal element with multi-nozzles. The result shows that the bubble size distribution and mean bubble size data agree well with the data obtained by a photographic method.
- 一般社団法人日本機械学会の論文
著者
関連論文
- Diffusion of Bubbles in Two-Phase Flow : The 1st Report, On the Method for the Measurement of the Diffusivity of the Bubble
- Diffusion of Bubbles in Two-Phase Flow : 2nd Report, Diffusion of a Single Bubble and Eddy Diffusivity of Heat in Single-Phase Turbulent Flow
- The Relationship between the Apparent Viscosity and the Void Fraction in Two-Phase Flow
- A Study on the Measurement of the Local Void Fraction by the Optical Fibre Glass Probe : 1st Report, On the Method for the Measurement of the Local Void Fraction in a Liquid Metal Two-Phase Flow
- A Study on the Measurement of Bubble Size Distribution in the Upward Bubbly Flow