Discharge Coefficients for 360-Deg. Bend Flowmeters
スポンサーリンク
概要
- 論文の詳細を見る
Calculations have been made of the pressure differential between the outside and inside curves of a 360-deg. bend flowmeter, and a theoretical formula for discharge coefficients in the case of turbulent flow was presented. Some theoretical considerations were also given to the discharge coefficients in the case of laminar flow. The discharge coefficients for five 360-deg. bend flowmeters with radius ratio in the range from 7 to 28 were measured in the Reynolds number range from 2×10^2 to 3×10^5. Empirical formulas for the discharge coefficients, which are backed by theoretical considerations and found in good agreement with experiments, were presented for both cases of laminar and turbulent flow.
- 一般社団法人日本機械学会の論文
著者
-
Miyakawa Takashi
Assistant Professor Hachinohe Institute Of Technology
-
ITO Hidesato
Professor, Institute of High Speed Mechanics, Tohoku University
-
Ito Hidesato
Professor Institute Of High Speed Mechanics Tohoku University