Analysis of the Dynamic Characteristics of Cross-Flow Heat Exchangers with Both Fluids Unmixed : On the Transient Responses to a Step Change in the Inlet Temperature
スポンサーリンク
概要
- 論文の詳細を見る
The transient responses to a step change in an inlet temperature are analyzed as an important example of dynamic characteristics of cross-flow heat exchangers with both fluids unmixed. The numerical calculations are performed by two methods, namely, a method expanding a finite difference method used by Myers et al. to calculate accurately in the case where temperature changes discontinuously, and a central finite difference method to calculate more accurately with a small number of nodes in large values of a heat capacity of a solid wall. Consequently, the effects of an initial condition and the various parameters concerning heat transfer performance on the transient responses in the temperature efficiency are shown.
- 一般社団法人日本機械学会の論文
著者
-
Izumi Ryotaro
Professor
-
Izumi Ryotaro
Professor Faculty Of Engineering Nagoya University
-
YAMAGUCHI SHIGEKI
Professor, Nagoya Institute of Technology
-
YAMASHITA Hiroshi
Assistant, Faculty of Engineering, Nagoya University
-
Yamaguchi Shigeki
Professor
-
Yamaguchi Shigeki
Professor Nagoya Institute Of Technology
-
Yamashita Hiroshi
Assistant Faculty Of Engineering Nagoya University
関連論文
- AN EXPERIMENTAL STUDY ON THE TURBULENCE CHARACTERISTICS OF A COAXIAL ROUND JET
- A STUDY ON THE TURBULENT MIXING OF A CO-AXIAL ROUND JET CONSIDERING THE VARIATION OF THE EDDY REYNOLDS NUMBER
- AN EXPERIMENTAL STUDY ON THE TURBULENCE CHARACTERISTICS OF AN OPPOSED JET ISSUED AGAINST A UNIFORM STREAM : MEASUREMENT OF TURBULENCE QUANTITIES WITH A SINGLE HOT WIRE
- An Analysis of Heat Exchanger Considering the Temperature Distribution Perpendicular to Heat Exchanger Surface
- Analysis of the Dynamic Characteristics of Cross-Flow Heat Exchangers with Both Fluids Unmixed : On the Transient Responses to a Step Change in the Inlet Temperature
- Performance of the Cross-Flow Heat Exchanger with Variable Physical Properties : 1st Report, In Case where the Overall Heat Transfer Coefficient Is Variable