Investigation of Instrumented Impact Test and Loading Rate Dependency of Fracture Toughness in Brittle Polymers
スポンサーリンク
概要
- 論文の詳細を見る
In the present study, the effect of the specimen size on the vibrational wave superimposed on the load-deflection curve of polymers is first investigated. Next, in the instrumented Charpy test, a shock-absorbing material is used in order to prevent the generation of a vibrational wave superimposed on the load-deflection curve, and its validity is examined. Further, differences in the impact response curves obtained by the instrumented Charpy test and the one-point bend test are compared and discussed. The results of this study are summarized as follows. (1) The vibrational wave can be prevented by the use of a small specimen which shortens the period of the vibrational wave. (2) The load value is lowered by the use of shock-absorbing material. (3) The differences in the impact response curves and the fracture times obtained from the instrumented Charpy impact test and the one-point bend test are rather large at the lower impact velocity of 3.10m/s; however, the obtained K_<Id> values are nearly coincident .
- 一般社団法人日本機械学会の論文
- 1992-07-15
著者
-
Kobayashi T
Department Of Production Systems Engineering Toyohashi University Of Technology
-
Kobayashi T
Faculty Of Engineering Toyohashi University Of Technology
-
Miyata H
Kurita Water Ind. Ltd. Atsugi‐shi Jpn
-
Kobayashi Toshiro
Faculty Of Engineering Toyohashi University Of Technology
-
YAMAMOTO Isamu
Faculty of Engineering, Toyohashi University of Technology
-
MIYATA Hiroshi
Nissan Motor Co., Ltd.
-
Miyata Hiroshi
Nissan Motor Co. Ltd.
-
Yamamoto Isamu
Faculty Of Engineering Toyohashi University Of Technology
関連論文
- In-situ Observations of Fracture Processes in 0.6μm and 9.5μm SiC_P/6061Al Composites
- Fracture Toughness of a 6061Al Matrix Composite Reinforced with Fine SiC Particles
- Fracture Toughness Evaluation and Specimen Size Effect
- Thermo-Mechanical Fatigue of a SiC_w/6061Al Composite
- Relative Sensitivity Factors for Analyzing Carbon and Nitrogen in Steels by Glow Discharge Mass Spectrometry
- Investigation of Instrumented Impact Test and Loading Rate Dependency of Fracture Toughness in Brittle Polymers
- Granulocyte functions and changes in ability with age in newborns ; Report no. 2 : Activation of granulocyte functions by cytokines
- Granulocyte functions and changes in ability with age in newborns ; Report no. 1 : Flow cytometric analysis of granulocyte functions in whole blood
- Experience with the Use of Salazosulfapyridine for Intractable Diarrhea after Hematopoietic Stem Cell Transplantation
- Von Willebrand disease : a case with very mild hemorrhagic episodes
- Progress in the Instrumented Charpy Impact Test