広い速度勾配範囲に用いる回転粘度計 : レオメーター
スポンサーリンク
概要
- 論文の詳細を見る
For the purpose of studying the molecular conditions in aqueous solutions of biologically important macromolecules, we frequently measure the viscosity of their dilute solutions. Since the mean shear rate in an Ostwald type viscometer is usually over 1000 sec^<-1>, the results cannot be treated with Simha's equation. Therefore a viscometer with a long capillary tube was designed to reduce the shear rate down to about 100 sec^<-1>. Recently we designed a coaxial cylinder type (Couette type) viscometer to measure viscosity at lower shear rates for studying large molecules having small rotary diffusion coefficients. The onter and inner cylinders are made of "Carbate". The inner cylinder is hollow so as to make the apparent density slighty smaller than water, and is supported by small pivot bearings at the top and the bottom. The pivot is made of iridosmine alloy to avoid any corrosion due to the solution to be measured. The cup bearing was made of synthetic saphire. The outer cylinder is supported by precision preloaded ball bearings, and immersed in oil, the temperature of which is kept constant. The outer cylinder has a pulley which is made to rotate through a rubber belt by the motor. The motor is a shunt type controlled by thyratrons. When the voltage of the power supply was kept constant, the speed of the motor is constant within 0.2% at any speed between 30 to 3000 r.p.m. The gap between the inner and the outer cylinder is 1 mm. The bottom part is designed as a cone-and-plate type so as to make the shear rate uniform all over the gap between both cylinders. The total volume of the gap is about 4 ml. For measurements, however, 7 ml. of solution is used in order to minimize the interaction between the upper surface of the inner cylinder and the free surface of the solution. An aluminum disk is on the axis of the inner cylinder and rotates with it. The edge of the disk is in the gap of a permanent magnet, and receives braking torque when the inner cylinder rotates. The strength of the torque is proportional to the rotational speed of the disk, and the value may be calibrated by placing liquid of known viscosity in the gap. In order to measure the viscosity of a solution, the solution is placed in the gap, and while rotating the outer cylinder at various speeds, the rotational speed of the inner cylinder and the difference of the rotational speed of the inner and the outer cylinders are measured. In this way viscositty of the solution may be measured at various points over a wide range of shear rate. We have measured non-Newtonian viscosity of myosin-B, tobacco mosaic virus, nucleic acid, collagen, polyacrylic acid, etc. over the shear rate range of 1 to 100 sec^<-1>. The upper limit for the shear rate is due to the method of measuring the rotational speed. If the rotational speed should be measured by a suitable electronic method instead of the present naked eye and a stopwatch method, the upper limit would be raised considerable. In order to lower the lower limit, we are trying to reduce the bearing friction.
- 社団法人日本材料学会の論文
- 1959-04-15
著者
関連論文
- セリサイト・サスペンジョンの流動特性 : レオロジー一般
- ライフサイエンスと情報処理
- 広い速度勾配範囲に用いる回転粘度計 : レオメーター
- コラーゲンのX線的研究
- 1-51.鼠の尾のコラーゲンの分子の大きさと形について(高分子,生物化学)(第11回定期講演會講演要旨)
- T系バクテリオフアージの電子顕微鏡的觀察の際に認められる変形
- 1-69.X線々量計(東京大学理工学研究所第6回定期講演會プログラム)
- 生物と環境 III : 人間の活動と自然
- 生物と環境 II : 微量成分の功罪
- 生物と環境 I : 物質と生物
- 生命の起源と進化 : 研究の歩み
- 生物物理化学(図書室)
- 酵素の構造と機能の関係
- コラーゲンの物理化学-1・2-
- タイトル無し