連続回転立体撮影法 : 新放射線診断法 : リアルタイム・ディスプレイ法の開発 : 正転逆転連続立体放映法
スポンサーリンク
概要
- 論文の詳細を見る
In order to view the cerebral vessels as continuous stereoscopic views, from left lateral, through anteroposterior, to right lateral projections, a new stereoscopic X-ray diagnostic device was devised. A gantry, which was equipped with an X-ray tube (Circlex 0.6W/0.8PG 38B) and a 9" image intensifier (Philips 9/5 High Lens) was rotated through 180° in 1.8 seconds by a motor power unit (Tsubaki SCU Motor: Type 022DMLB). A television unit, AX-2000A, with a Plumbicon (QX-1072) camera tube, was used (Stereotom Type II). In the previous study using cine, a cine film stereoprojector showed the adjacent two frames of cine film simultaneously, such as frames 1 and 2, 2 and 3, 3 and 4, and so on, consecutively. Because some intracranial lesions require emergency surgery immediately after angiography, a real time display method of serial rotatostereography was necessary. In order to show the consecutive adjacent two frames of a video disc simultaneously, using the same method as with the cine stereoprojector, a video disc recorder (VDR) (VM-1000M) and two video memories (Image Σ) were required. This VDR has the ability of advancing, stopping, and reversing the display of memories. A control unit was manufactured in order to display these memories advancing and reversing continuously. As a result of this continuous semirotation stereo display, the anteroposterior projection was reversed, showing the posteroanterior view during "reversing mode." Thus a lead relay circuit was manufactured to prevent this phenomenon. Recording was done using a memory disc recorder (FOM 2200F), which has the ability of recording 10,000 frames per disc. Each frame can also be recorded on imaging film using O・X Multi Camera 400X. Finally, stereoscopic views of cerebral circulation, using a single injection of contrast media and rapid rotation of the gantry, were obtained using two cathode-ray tubes (CRTs) and a stereoviewer (Continuous Semi-rotation Classical Stereo Display Method). Stereoscopic views were also obtained using a single CRT, which displayed the images in a semi-rotating fashion similar to a oscillating fan head (Continuous Semi-rotation New Stereo Display Method).
- 日本脳神経外科学会の論文
- 1986-10-15
著者
関連論文
- 469.連続回転立体撮影法 : Continuous semi rotation real time stereo display法の開発と技術的諸問題(第41回総会会員研究発表)(間接, 立体撮影他)
- 300.連続回転ステレオ像観察装置(第40回総会会員研究発表)(診断用装置-4 装置)
- 頭頂部深部白質脳動静脈奇形に前脈絡叢動脈瘤を合併した1例 - Interhemispheric trans-precuneus approach -
- 連続回転立体撮影法-新放射線診断法-2-シネ撮影法の応用並びにシネフィルム立体視法
- 連続回転立体撮影法 : 新放射線診断法 : リアルタイム・ディスプレイ法の開発 : 正転逆転連続立体放映法
- 連続回転立体撮影法 : 新放射線診断法(第3報) : 連続回転立体撮影装置(ST Type I)ならびにシネフィルム立体投影機の試作
- 285.Peak hold式DSAの臨床応用(第41回総会会員研究発表)(ディジタルイメージング-3 DSA-1)
- 8.Peak Hold式DSAの基礎的研究(I.Digital Subtraction Angiographyの臨床利用について)(第12回放射線技術)
- 8.Peak Hold式DSAの基礎的研究(I.Digital Subtraction Angiographyの臨床利用について)(第12回 放射線技術シンポジウム予稿)
- 214.ハイコントラストイメージアンプリファイアの性能評価(第39回総会会員研究発表)(診断用装置-5)
- 125.循環器シネ撮影における撮影条件の最適化(第37回総会 会員研究発表)(撮影-5 造影撮影2)
- 183.X線管電流調整の自動化(第36回総会会員研究発表)(診断用装置1装置特性)
- 172.プログラム可能な撮影条件設定法(第35回総会会員研究発表)(診断用装置2装置特性他)
- 連続回転立体撮影法-新放射線診断法 第II報 シネ撮影法の応用並びにシネフィルム立体視法
- 脳血管同時3相厚層断層撮影法. 第1報 円軌道移動方式による基礎実験
- 198.循環器系X線診断システム : その1,集中制御方式について(第32回総会会員研究発表)(診断用装置-2 X線TV)
- 15.マンモグラフィーにおける定管電圧撮影(撮影理論II管電圧・管電流測定)(第30回総会会員研究発表)
- 54.直接撮影方式による胃X線検診車 : 第1報設計(診断用装置I発生器, 装置管理)(第30回総会会員研究発表)
- 最高級X線高電圧装置SHD150G (医用機器)
- 最近の島津循環器X線検査システム(製品紹介) (医用機器)
- 55.胃検診車における電源設備の実情(診断用装置I発生器, 装置管理)(第30回総会会員研究発表)
- 111.チューブシフト可能なX線TV装置に於けるX線撮影の自動化(X線テレビ)(第28回総会)
- 連続回転立体撮影法--新放射線診断法-1-脳血管撮影法並びに脳室造影法への応用