The Construction and Test Operation of INS-Linear Electron Accelerator
スポンサーリンク
概要
- 論文の詳細を見る
This is the third article in the series on the 6 MeV linear accelerator to be used for the injector of 1 BeV electron synchrotron, and describes the construction and early tests of the accelerator including the fabrication and the assembly of the components (accelerator guide, waveguide system electron gun and vacuum system etc.) The accelerator guide has been carefully fabricated so as to match the designed structure reported in the preceding paper. An rf driven prebuncher has been provided in order to obtain a narrow energy spread and high trapping efficiency. The results obtained the preliminary tests were the energy spread of about 3 percent at 6.6 MeV, whereas the spread increased up to 5-6 percent without the prebuncher.
- 社団法人日本物理学会の論文
- 1961-11-05
著者
-
Tanaka Jiro
Institute For Nuclear Study University Of Tokyo
-
TANAKA J.
Institute for Nuclear Study University of Tokyo
-
TANAKA Jiro
Institute For Nuclear, Study University of Tokyo
関連論文
- A Linear Electron Accelerator as the Injector of 1 BeV Synchrotron
- Precise Centre Settling Device for Quadrupole Magnets
- On the Operation of Electron Synchrotron at the Institute for Nuclear Study, Tokyo
- A Thin Vacuum Gate Value of Large Aperture
- The Construction and Test Operation of INS-Linear Electron Accelerator