熔鋼温度測定に關する二, 三の研究
スポンサーリンク
概要
- 論文の詳細を見る
No satisfactory method of measuring temperature of a steel bath, when in the open-hearth-furnace or the arc-furnace, has yet been devised. Usually, for convenience, the temperature of steel baths is conjectured indirectly from the values that obtained by an optical pyrometer as the temperature of the liquid steel in the spoon at sampling. This procedure is, however, quite unreliable, in accordance with the lack of knowledge about the personal error of an observer, the emissive power of liquid steel in the spoon, a fall of the temperature of the spoon under ladling from the furnace, etc., that we can hardly know the accurate temperature of the steel bath. The author has attempted to improve the method and has made several studies on the points just mentioned above. The results are as follow : 1) The personal error was determined by the simultaneous use of a standard lamp and a standard optical pyrometer. In addition to this, the degree of skill of the observer was assumed from the dispersion of data. We cannot neglect the effect of personal errors which attain±10° in the maximum. We find also that the degree of skill of the observer does not depend neither on the age nor on the duration of practice. 2) The true temperature of liquid steel in the spoon was measured by the special Fe-W thermocouple, which was of a direct immersion type and formed a hot junction through the liquid steel. The heat capacity of this thermocouple is very small and the measurement can be finished in 3-5 seconds. We compared the true temperature by the Fe-W thermocouple with the brightness temperature by the optical pyrometer, and obtained the emissivits of each kind of steel in the spoon. Namely, in case of the arc-furnace, the average values are 0.55 for Ni-Cr steel, 0.56 for Cr-Mo steel, 0.53 for Ni-Cr-Mo steel and 0.52 for carbon steel. In the case of the open-hearth-furnace, where the data are not enough, the total average value is 0.52. 3) The cooling of the liquid steel in a spoon during ladling was determined from the evaluation and the experiments. The fall of temperature is affected by the thickness of slags which cover the spoon. While the thickness of slags varies from 0.4 to 1.0 cm, the fall of temperature takes the value from 40 to 20℃.
- 社団法人日本鉄鋼協会の論文
- 1939-11-25
著者
関連論文
- 鋼の階段燒入に關する研究 (III) : オーステンパリング的階段燒入及び短時間加熱階段燒入を行つた炭素鋼の組織分布, 硬度分布及び殘留應力分布
- 鉄鋼における研究および技術の今後の問題
- 鍛造用型鋼に關する研究
- 67. 階段燒入法に於ける鋼の變態に就て
- 鋼の燒入應力に關する研究
- 鋼の階段焼入に關する研究第 2 報その 2 : 炭素鋼試驗片に階段焼入を行ふ際に於ける内部應力發生機構の考察
- 鋼の階段焼入に關する研究第 2 報その 1
- 鋼の階段燒入に關する研究(第 1 報その 2)
- 鋼の階段焼入に關する研究 (I)
- 熔鋼の輻射率に關する研究
- 熔鋼温度測定に關する二, 三の研究