SUS304 ステンレス鋼の低温鋭敏化に及ぼす応力の影響
スポンサーリンク
概要
- 論文の詳細を見る
By using carbide nucleation-heat-treated SUS304 stainless steel specimens, the effect of various type of stresses applied during 500℃ isothermal heat treatment on Low Temperature Sensitization (LTS) was examined. The Degree of Sensitization (DOS) was detected by means of the Electrochemical Potention-kinetic Reactivation (EPR) test and Strauss test. The main results of the study are as follows : 1) When constant tensile stress is applied to the specimens during isothermal heat treatment, the LTS was accelerated more than unstressed specimens. The degree of acceleration was larger when the applied stress was larger. The acceleration of the LTS was also seen even when the stress less than proof stress at the test temperature. 2) The electrochemical potentiokinetic reactivation ratio of the specimens after 100h of the LTS test corresponded to strain rather than stress. 3) When alternating stress was applied to the specimens during the isothermal heat treatment, the LTS was accelerated even more than when constant tensile strees was applied.
- 社団法人日本鉄鋼協会の論文
- 1990-09-01
著者
関連論文
- 315 SUS304ステンレス鋼のEPR試験に及ぼす測定面積の影響(SCC・腐食摩耗・計測)(日本機械学会東北支部・腐食防食協会東北支部共催セッション)
- 伸線加工した共析鋼の疲労き裂進展特性
- ステンレス鋼の疲労挙動に及ぼすアルミナコーティングの影響
- オーステナイト系ステンレス鋼の鋭敏化度の測定におけるEPR試験とStrauss試験の対応
- 粒子強化アルミ合金ダイカストの室温・高温疲労強度特性
- SUS304 ステンレス鋼の低温鋭敏化に及ぼす応力の影響
- 共析鋼極細線の疲労強度とその影響因子
- 2円孔列を有する薄板のねじれ
- 2 円孔列を有する薄板のねじれ