高炉炉頂圧発電の現状について(<特集>鉄鋼業における省エネルギー)
スポンサーリンク
概要
- 論文の詳細を見る
Recently, top gas pressure recovery turbine plants have been installed in some steel making plants for energy saving. Eleven turbine plants have been operated including two test plants in Japan. Total operation time of the first plant (Kawasaki Stecl Corp. Mizushima Works No.2 B. F) was approximately 26 400 hours. There are two basic types of turbines for energy recovery ; wet and dry. A radial flow turbine is of the wet type, and an axial flow turbine is of the dry type. Each turbine has special devices designed for prevention of corrosion, erosion and clogging of the turbine by dust and moisture-laden gas. These turbine systems have had no effect in any way on the blast furnace operation. Recovery turbine output of the first plant reaches 20 to 30% of blast blower input energy and its availability, approximately 85%, is over the average of self-thermal power plants in steel making plants. In the future, economical plants will be developed for further improvement of turbinc output and higher reliability of turbine systems including gas cleaning equipment.
- 社団法人日本鉄鋼協会の論文
- 1978-11-01
著者
関連論文
- 81 高炉排ガス乾式集じんパイロットプラントについて(分析・ガス流れ・耐火物・省エネルギ, 製銑, 日本鉄鋼協会 第 98 回(秋季)講演大会)
- 234 CO ガス回収精製装置の設備概要と操業実績(連鋳(ステンレス鋼・電磁攪拌)・転炉 (II), 製鋼, 日本鉄鋼協会第 111 回(春季)講演大会)
- 10 高炉小ベルホッパガス回収設備とその操業(高炉設備・原子力製鉄, 製銑, 日本鉄鋼協会 第 101 回(春季)講演大会)
- 248 燃焼等価(AoI 等価)方式による混合ガス配給システムの開発(形鋼の二次加工・加工性・新製造法・熱処理・ダイス寿命・炉の制御, 加工, 日本鉄鋼協会 第 97 回(春季)講演大会)