Simple measurement technique of luminance distribution by means of TV camera and microcomputer
スポンサーリンク
概要
- 論文の詳細を見る
In recent years, microcomputers have been widely used in connection with sensors or transducers for special use in applied measurements and controls. Visual photometric methods have been largely replaced commercially by physical photometric methods and their application techniques.In this study the authors made a trial model of an interface between a TV camera and a microcomputer. The interface consists of three main parts : a sample & hold circuit, an A-D converter circuit, and a timing control circuit.Work was carried out for simple measurement of the luminance distribution pattern of a luminaire with FL20 W×2 on a color CRT device which displays eight gray levels.
- 社団法人照明学会の論文
著者
-
Iizuka Masayuki
Nagoya Institute Of Technology.
-
Iizuka Masayuki
Nagoya Institute Of Technology
-
TOHYAMA Akira
Yokogawa Hokushin Electric LTD.
-
FUKUI Shoji
Nagoya Institute of Technology.
-
Tohyama A
Yokogawa Hokushin Electric Ltd.
関連論文
- Visual Appearance of Color and Image Quality of Computer-Generated 3-D Transparent Objects
- Simple measurement technique of luminance distribution by means of TV camera and microcomputer