電気集じん装置の内部バイパス流が集じん率に及ぼす影響
スポンサーリンク
概要
- 論文の詳細を見る
In order to calculate the collection efficiency in an Electrostatic Precipitator (EP), it is necessary to take into account the effect of gas-sneakage which pass through the upper and down side of effective collection space. There have been reports on the calculation of the collection efficiency with the effect of gassneakage. However, since the calculation method used in these reports is relatively complicated and needs to input the dust particle-size distribution, in practice it is difficicult to apply the method easily. In this paper, the effect of gas-sneakage on the collection efficiency in EP is calculated on the base of new corrected formula of Deutsch's equation, which gives collection efficiency over the wide range of specific collection area (SCA), by using the apparent migration velocity of dust particle for parameter. The results of calculation are graphed and the several impotant characteristics related to the effect of gas-sneakage on the collection efficiency are explaned by the examination in these graphs.
- 山口大学の論文
著者
関連論文
- パソコンおよび二次元 CAD による熱交換器の設計・製図例
- マニュアルおよび CAD による設計・製図教育の比較と検討
- パソコンおよび CAD による機械設計について
- 任意のSCAにおけるMattsの式の定数と見かけの粒子移動速度の推算
- 電気集塵装置におけるDeutschの式の修正式の検討-3-集塵性能特性曲線上での検討
- 微差圧計の試作と低レイノルズ数領域における管摩擦抵抗係数の測定
- 電気集じん装置においてダスト粒径分布特性が集じん性能に及ぼす影響
- 電気集じん装置の内部バイパス流が集じん率に及ぼす影響