Modeling on Hydrogen Absorption in Tetrahydrofuran Hydrate
スポンサーリンク
概要
- 論文の詳細を見る
The storage rate and amount of hydrogen in tetrahydrofuran hydrate were investigated by means of pressure–volume–temperature measurement under three temperature conditions. The absorption process of hydrogen in tetrahydrofuran hydrate was expressed as a dynamical model based on classical shrinking core model, which included two steps: hydrogen inclusion (containing adsorption, entrapment, and delocalization processes) at the surface of tetrahydrofuran hydrate and hydrogen diffusion through the formed layer of hydrogen+tetrahydrofuran mixed hydrate. The rate constant of surface reaction and/or diffusion coefficient of hydrogen depended on the porosity of small cages in tetrahydrofuran hydrate at equilibrium state. The storage amount of hydrogen at all temperatures would reach the maximum value of 2.0 mol (hydrogen)/mol (tetrahydrofuran) at a certain pressure. At the same pressure, the storage amount of hydrogen increases as the temperature decreases.
- 2012-07-01
著者
-
Inoue Yoshiro
Division Of Cardiology Saitama Medical Center
-
Hashimoto Shunsuke
Division Of Chemical Engineering Graduate School Of Engineering Science Osaka University
-
Yamamoto Keishi
Division Of Chemical Engineering Graduate School Of Engineering Science Osaka University
-
TSUDA Takaaki
Division of Chemical Engineering, Graduate School of Engineering Science, Osaka University
-
Tsuda Takaaki
Division Of Chemical Engineering Graduate School Of Engineering Science Osaka University
関連論文
- Clinical Outcomes after Stenting with or without IVUS Guidance(Intravascular Endoscopy/Intravascular Ultrasound 4 (I), The 69th Annual Scientific Meeting of the Japanese Circulation Society)
- OJ-203 Systemic and Virtual Histological Determinant Factors of Coronary Distensibility(OJ34,Atherosclerosis (Clinical/Pathophysiology) (IHD),Oral Presentation (Japanese),The 73rd Annual Scientific Meeting of The Japanese Circulation Society)
- PJ-338 Relationship between coronary artery distensibility and plaque composition determined by Virtual Histology-IVUS(Intravascular endoscopy/Intravascular ultrasound(06)(I),Poster Session(Japanese),The 72nd Annual Scientific Meeting of the Japanese Circ
- PJ-005 Longitudinal Inhomogeneity of Coronary Distensibility in Acute Coronary Syndrome Related Plaques(Acute coronary syndrome, basic/clinical-6, The 71st Annual Scientific Meeting of the Japanese Circulation Society)
- PJ-777 IVUS Reduces Restenosis Rate after Bare-Metal Stenting in Patients with Acute Myocardial Infarction(Intravascular endoscopy/Intravascular ultrasound-7 (I) PJ135,Poster Session (Japanese),The 70th Anniversary Annual Scientific Meeting of the Japanes
- PE-369 Parameters of Cardiac Dyssynchrony Predicts Chronic Cardiac Function after Acute Myocardial Infarction(Echo/Doppler-9 (I) PE62,Poster Session (English),The 70th Anniversary Annual Scientific Meeting of the Japanese Circulation Society)
- Real-time 3D Echo Cardiac Wall Motion Dyssyncrony Reflect Cardiac Function in Patients of Acute Myocardial Infarction(Echo/Doppler 1 (I), The 69th Annual Scientific Meeting of the Japanese Circulation Society)
- OE-071 Inhomogeneous Coronary Compliance Is Related to Plaque Vulnerability(Acute Coronary Syndrome, Basic/Clinical 3 (IHD) : OE9)(Oral Presentation (English))
- Effect of Bending Direction on Mixing Performance of Zigzag Microchannels
- Effect of Bending Direction on Mixing Performance of Zigzag Microchannels
- Modeling on Hydrogen Absorption in Tetrahydrofuran Hydrate
- Geometric Structure and Formation Condition of Corded Isolated-Mixing Region in Impeller Agitated Vessel