Anatomical and Biomechanical Analyses of the Unique and Consistent Locations of Sacral Insufficiency Fractures
スポンサーリンク
概要
- 論文の詳細を見る
- 2009-02-15
著者
-
Crawford Neil
Spinal Biomechanics Research Laboratory Barrow Neurological Institute
-
KARIS John
Barrow Neurological Inatitute, Phoenix
-
Karis John
Barrow Neurological Inatitute Phoenix
-
Crawford Neil
Spinal Biomechanics Laboratory Barrow Neurological Institute St Joseph Hospital And Medical Center
-
LINSTROM Nathan
Barrow Neurological Institute, St Joseph Hospital and Medical Center
-
HEISERMAN Joseph
Barrow Neurological Institute, St Joseph Hospital and Medical Center
-
KORTMAN Keith
Sharp Memorial Hospital
-
BAEK Seungwon
Spinal Biomechanics Laboratory, Barrow Neurological Institute, St Joseph Hospital and Medical Center
-
ANDERSON Russell
Arizona State University, Harrington Department of Bioengineering
-
PITT Alan
Barrow Neurological Institute, St Joseph Hospital and Medical Center
-
ROSS Jeff
Barrow Neurological Institute, St Joseph Hospital and Medical Center
-
DEAN Bruce
Department of Neurological Surgery, Barrow Neurological Institute, St Joseph Hospital and Medical Ce
-
Ross Jeff
Barrow Neurological Institute St Joseph Hospital And Medical Center
-
Anderson Russell
Arizona State University Harrington Department Of Bioengineering
-
Karis John
Barrow Neurological Institute St Joseph Hospital And Medical Center
-
Crawford Neil
Spinal Biomechanics Barrow Neurological Institute
-
Baek Seungwon
Spinal Biomechanics Laboratory Barrow Neurological Institute St Joseph Hospital And Medical Center
-
Pitt Alan
Barrow Neurological Institute St Joseph Hospital And Medical Center
-
Dean Bruce
Department Of Neurological Surgery Barrow Neurological Institute St Joseph Hospital And Medical Cent
-
Linstrom Nathan
Barrow Neurological Institute St Joseph Hospital And Medical Center
-
Heiserman Joseph
Barrow Neurological Institute St Joseph Hospital And Medical Center
関連論文
- New Percutaneously Inserted Spinal Fixation System
- Biomechanical Assessment of Anterior Lumbar Interbody Fusion With an Anterior Lumbosacral Fixation Screw-Plate : Comparison to Stand-Alone Anterior Lumbar Interbody Fusion and Anterior Lumbar Interbody Fusion With Pedicle Screws in an Unstable Human Cadav
- Effect of Recombinant Human Bone Morphogenetic Protein-2 in an Experimental Model of Spinal Fusion in a Radiated Area
- Biomechanical Comparison of Anterior Versus Posterior Lumbar Threaded Interbody Fusion Cages
- Biomechanical Comparison of Anterolateral Plate, Lateral Plate, and Pedicle Screws-Rods for Enhancing Anterolateral Lumbar Interbody Cage Stabilization
- Unilateral Cervical Facet Dislocation : Injury Mechanism and Biomechanical Consequences
- Letters
- Biomechanical Effects of Progressive Anterior Cervical Decompression
- Biomechanical Analysis of a Resorbable Anterior Cervical Graft Containment Plate
- Biomechanical Analysis of Rigid Stabilization Techniques for Three-Column Injury in the Lower Cervical Spine
- Biomechanics of Stabilization After Cervicothoracic Compression-Flexion Injury
- The Biomechanical Effects of Cervical Multilevel Oblique Corpectomy
- Bilateral Temporal Hypometabolism in Epilepsy
- Bioresorbable Polylactide Interbody Implants in an Ovine Anterior Cervical Discectomy and Fusion Model : Three-Year Results
- Anatomical and Biomechanical Analyses of the Unique and Consistent Locations of Sacral Insufficiency Fractures
- A New Stand-Alone Cervical Anterior Interbody Fusion Device : Biomechanical Comparison With Established Anterior Cervical Fixation Devices
- Increase in Spinal Canal Area After Inverse Laminoplasty : An Anatomical Study