Analysis of Phase Shift Tolerance in a Coherent OCDM System Using FBG Phase En/Decoders
スポンサーリンク
概要
- 論文の詳細を見る
We previously reported, for a coherent optical code division multiplexing (OCDM) system using fiber Bragg grating (FBG) phase en/decoders, that the signals exhibited phase shift tolerance for a difference between the light source wavelength and the Bragg wavelength of an FBG phase en/decoder when the two signals were multiplexed. However, the phase conditions of only the central wavelength among the ones forming a pulse were analyzed. For a more specific consideration, we calculated the phase of each wavelength forming the decoded pulse. In this report, the measured and calculated reflecting properties were compared and the reliability of the method was confirmed. We calculated the phase conditions of the decoded pulses and clarified the phase characteristics with regard to the phase modulation and the interference between pulses overlapped during decoding. For the realization of an asynchronous access, the FBG phase en/decoders should be designed so that the spreading time is the inverse of 2×(transmission rate).
- (社)電子情報通信学会の論文
- 2008-08-01
著者
-
NAKAMURA Tomoaki
Department of Cardiology, Matsusaka Central General Hospital
-
Oshiba Saeko
Department Of Electronics Kyoto Institute Of Technology
-
Kotani Yasuhiro
Department Of Cardiovascular Surgery Okayama University Graduate School Of Medicine And Dentistry
-
MORITOMO Renichi
Department of Electronics, Kyoto Institute of Technology
-
Moritomo Renichi
Department Of Electronics Kyoto Institute Of Technology
-
Nakamura Tomoaki
Department Of Electronics Kyoto Institute Of Technology
関連論文
- Unique Myocardial Fibrosis Pattern by Late Gadolinium Enhanced Magnetic Resonance Imaging in a Patient With Isolated Noncompaction of the Ventricular Myocardium
- PJ-066 Cardiac Magnetic Resonance Imaging can Reveal a Variety of Myocardial Damage in Patients with Takotsubo Cardiomyopathy(PJ011,CT/MRI (Myocardium) 4 (I),Poster Session (Japanese),The 73rd Annual Scientific Meeting of The Japanese Circulation Society)
- Computer Simulation of Ion Beam Extraction by Finite Element Method
- Right Ventricular Outflow Tract Reconstruction in Patients With Persistent Truncus Arteriosus : A 15-Year Experience in a Single Japanese Center
- Left Ventricular Retraining and Anatomic Correction in Teenage Patient With Congenitally Corrected Transposition of the Great Arteries
- Diagnosis-Based Differences in Response of Global Ventricular Performance to Modified Ultrafiltration in Children
- Effect of Modified Ultrafiltration on Postoperative Course in Neonates With Complete Transposition of the Great Arteries Undergoing Arterial Switch Operation
- Review of Coronary Artery Disease in Patients With Infrarenal Abdominal Aortic Aneurysm
- Gasless Endoscopic Thyroid and Parathyroid Surgery Using a New Retractor
- Reduction of Organic Halides with Tri-2-furylgermane: Stoichiometric and Catalytic Reduction
- Analysis of Phase Shift Tolerance in a Coherent OCDM System Using FBG Phase En/Decoders
- TSUNAMI SCOUR AROUND A SQUARE STRUCTURE
- Prevalence and Signal Characteristics of Late Gadolinium Enhancement on Contrast-Enhanced Magnetic Resonance Imaging in Patients With Takotsubo Cardiomyopathy
- Grounding of Word Meanings in Latent Dirichlet Allocation-Based Multimodal Concepts