Characteristics of Bubble Departure Frequency in a Low-Pressure Subcooled Boiling Flow
スポンサーリンク
概要
- 論文の詳細を見る
In order to measure the bubble departure frequency, a flow visualization system was set up on a vertical annulus test section with a heater rod by using a high-speed camera. In this study, we developed an efficient methodology of image processing for obtaining the bubble departure frequency data. Bubble nucleation was investigated under various thermal hydraulic conditions of water, which correspond to pressures from 167 to 346 kPa, mass fluxes from 214 to 1869 kg/m2s, heat fluxes from 61 to 238 kW/m2, and subcooling degrees from 7.5 to 23.4 K. The characteristics of bubble departure frequency were analyzed with the present data. The measured data was compared with models available in existing literature and a more plausible model was proposed.
- 2010-07-01
著者
-
EUH Dongjin
Korea Atomic Energy Research Institute
-
OZAR Basar
School of Nuclear Engineering, Purdue University
-
HIBIKI Takashi
School of Nuclear Engineering, Purdue University
-
ISHII Mamoru
School of Nuclear Engineering, Purdue University
-
SONG Chul-Hwa
Korea Atomic Energy Research Institute
-
Ozar Basar
School Of Nuclear Engineering Purdue University
-
Ishii Mamoru
School Of Nuclear Engineering Purdue University
-
Song Chul-hwa
Korea Atomic Energy Res. Inst.
-
Hibiki Takashi
School Of Nuclear Engineering Purdue Univ.
-
Hibiki Takashi
School Of Nuclear Engineering Purdue University
関連論文
- Characteristics of Bubble Departure Frequency in a Low-Pressure Subcooled Boiling Flow
- Interfacial Area Transport of Bubbly Flow in a Small Diameter Pipe
- Flow Structure of Subcooled Boiling Water Flow in a Subchannel of 3 × 3 Rod Bundles
- 画像処理による細管内気液二相流界面輸送の計測(FR2 計測制御の最先端)
- ICONE11-36391 INTERFACIAL AREA TRANSPORT OF BUBBLY FLOW AT LOW LIQUID REYNOLDS NUMBER UNDER MICROGRAVITY ENVIRONMENT
- Computational Analysis of a Subcooled Boiling Flow with a One-group Interfacial Area Transport Equation
- Experiments on the Heat Transfer and Natural Circulation Characteristics of the Passive Residual Heat Removal System for an Advanced Integral Type Reactor
- ICONE11-36179 SAFETY ANALYSIS OF MULTIPLE-FAILURE OF PASSIVE SAFETY SYSTEMS IN SBWR-1200 SBLOCA
- ICONE11-36015 ONE-DIMENSIONAL DRIFT-FLUX MODEL FOR DOWNWARD TWO-PHASE FLOW
- Local Interfacial Structure of Subcooled Boiling Flow in a Heated Annulus
- ICONE11-36016 MECHANISTIC MODELING OF ACTIVE NUCLEATION SITE DENSITY IN BOILING SYSTEMS
- Bubble Lift-off Diameter and Nucleation Frequency in Vertical Subcooled Boiling Flow
- Experimental Study for Multidimensional ECC Behaviors in Downcomer Annuli with Direct Vessel Injection Mode during the LBLOCA Reflood Phase
- Influence of Key Parameters on the APR1400 In-Containment Refueling Water Storage Tank Hydrodynamic Loads