T_1-weighted MR Imaging of the Female Pelvis Using RADAR-FSE Sequence
スポンサーリンク
概要
- 論文の詳細を見る
Radial scanning is attracting increasing attention as a method of suppressing motion artifacts in magnetic resonance imaging. We compared the effectiveness of radial acquisition regime-fast spin echo (RADAR-FSE), a method of radial scanning, with conventional FSE in the T1-weighted imaging setting by scanning Gd-DTPA phantoms and 9 female patients (pelvic imaging). RADAR-FSE suppressed motion artifacts better than FSE but caused streak artifacts and diminished sharpness. Clinicians should be aware of these limitations.
- 2009-12-01
著者
-
Senoo Atsushi
Department Of Physical Therapy Tokyo Metropolitan University
-
Kohda Ehiichi
Department Of Radiology Toho University Ohashi Medical Center
-
Kohda Ehiichi
Department Of Diagnostic Radiology School Of Medicine Keio University
-
Senoo Atsushi
Department Of Radiological Sciences Tokyo Metropolitan University Graduate School Of Human Health Sc
-
NAGAMOTO Masashi
Department of Radiology, Toho University School of Medicine
-
GOMI Tatsuya
Department of Radiology, Toho University School of Medicine
-
Takizawa Masahiro
Mri System Division Hitachi Medical Corporation
-
HATTORI Naofumi
Division of Radiology, Toho University Ohashi Medical Center
-
NAKANO Tomoe
Division of Radiology, Toho University Ohashi Medical Center
-
CHIBA Toshiaki
Division of Radiology, Toho University Ohashi Medical Center
-
YOKOSE Masatomo
Clinical Application Department, Hitachi Medical Corporation
-
Gomi Tatsuya
Department Of Radiology Toho University Ohashi Medical Center
-
Nagamoto Masashi
Department Of Radiology Toho University Ohashi Medical Center
-
Nagamoto Masashi
Department Of Radiology Toho University Medical Center Ohashi Hospital
-
Chiba Toshiaki
Division Of Radiology Toho University Ohashi Medical Center
-
Nakano Tomoe
Division Of Radiology Toho University Ohashi Medical Center
-
Hattori Naofumi
Division Of Radiology Toho University Ohashi Medical Center
-
Yokose Masatomo
Clinical Application Department Hitachi Medical Corporation
関連論文
- A Comparison of Three Bimanual Coordinations : An fMRI Study
- A Case of Adenocarcinoma with Mixed Subtypes Displaying Ground-glass Opacity on High-Resolution CT
- Sporadic gastric neurofibroma underneath early cancer : MDCT gastrography and histological findings
- Neural Mechanism of Self-Initiated and Externally Triggered Finger Movements
- T_1-weighted MR Imaging of the Female Pelvis Using RADAR-FSE Sequence
- Neural Mechanism Responses in the Brain to Predetermined Periodic and Aperiodic Stimuli : Analysis of Visual Stimulation of Movement
- Brain Organization during Passive Touch and Tactile Discrimination and the Influence of Learning : a Functional MRI Study
- Evaluation of the changes in signals from the spleen using ferucarbotran
- Notes on the application of the Matsui-Kitamura stent-graft for endovascular repair of abdominal aortic aneurysm
- Revisit image control for pediatric chest radiography
- Imaging of congenital lipoid adrenal hyperplasia
- Measurement of Visceral Fat/subcutaneous Fat Ratio by 0.3 Tesla MRI
- The Diagnosis of Lung Cancer Using 1064-nm Excited Near-infrared Multichannel Raman Spectroscopy
- Evaluation of the acute adverse reaction of contrast medium with high and moderate iodine concentration in patients undergoing computed tomography
- Comparison of two-port and four-port irradiation in the bladder preservation therapy for locally invasive bladder cancer
- Coronary Artery CT Low-Density Plaque Area and Its Ratio to the Whole Area of a Non-Calcified Plaque at the Culprit Lesion in Patients With Unstable and Stable Coronary Artery Disease