Acoustic Leak Detection System for Sodium-Cooled Reactor Steam Generators Using Delay-and-Sum Beamformer
スポンサーリンク
概要
- 論文の詳細を見る
A new acoustic leak detection system for sodium-cooled reactor steam generators using a delay-and-sum beamformer is proposed. The major advantage of the delay-and-sum beamformer is that it could provide information on the acoustic source direction. An acoustic source of a sodium-water reaction is supposed to be localized, while the background noise of the steam generator operation is uniformly distributed in the steam generator tube region. Therefore, the delay-and-sum beamformer could distinguish the acoustic source of the sodium-water reaction from the steam generator background noise. In this paper, results of numerical analyses are provided to show the fundamental feasibility of the new method.
- 一般社団法人 日本原子力学会の論文
- 2010-01-01
著者
関連論文
- Development of Advanced Fuel Handling Machine for JSFR
- Electromagnetic Pumps for Main Cooling Systems of Commercialized Sodium-Cooled Fast Reactor
- Experimental Demonstration of Flow Diodes Applicable to a Passive Decay Heat Removal System for Sodium-Cooled Reactors
- A Feasibility Study on a Small Sodium Cooled Reactor as a Diversified Power Source
- A Thermoelectric-Conversion Power Supply System Using a Strontium Heat Source of High-Level Radioactive Nuclear Waste
- Electromagnetic Pumps for Main Cooling Systems of Commercialized Sodium-Cooled Fast Reactor
- Acoustic Leak Detection System for Sodium-Cooled Reactor Steam Generators Using Delay-and-Sum Beamformer
- A Thermoelectric-Conversion Power Supply System Using a Strontium Heat Source of High-Level Radioactive Nuclear Waste