Improvement of insulation performance of a porcelain long-rod insulator under contaminated conditions (特集 IWHV 2007 (5th International Workshop on High Voltage Engineering))
スポンサーリンク
概要
- 論文の詳細を見る
The higher contamination flashover voltage performance of a transmission line polymer insulator has been shown to be attributable not only to its surface hydrophobicity but also to its configuration. A larger ratio in the shed to core diameter of the transmission line polymer insulator brings about higher surface resistances in its individual trunks, and therefore the voltage applied to the entire insulator can be divided and allotted to these trunks, resulting in a higher flashover voltage. We expected a similar effect by applying a silicone rubber coating having hydrophobicity only to all the trunk surfaces of a porcelain long-rod insulator. We tested by the clean fog method and confirmed only about a 10% improvement. In this paper, the same such effect was evaluated by the salt fog test method, which confirmed a significant improvement. The detailed investigation results are presented.
- 社団法人 電気学会の論文
- 2007-12-01
著者
-
YAMADA Kazuma
Department of Electrical Engineering, Chubu University
-
SAKA Chiharu
Department of Electrical Engineering, Chubu University
-
SAKANISHI Kenji
Department of Electrical Engineering, Chubu University
-
MATSUOKA Ryosuke
Department of Electrical Engineering, Chubu University
-
Matsuoka Ryosuke
Department Of Electrical Engineering Chubu University
-
Saka Chiharu
Department Of Electrical Engineering Chubu University
-
Yamada Kazuma
Department Of Electrical Engineering Chubu University
-
Sakanishi Kenji
Department Of Electrical Engineering Chubu University
-
GAUTAM Basanta
Department of Electrical Engineering, Chubu University
-
SUMI Shin-ichi
Department of Electrical Engineering, Chubu University
-
SUMI Shin-ichi
Chubu University
-
Gautam Basanta
Department Of Electrical Engineering Chubu University
関連論文
- Evaluation Methods of Contamination Flashover Voltage Performance of Cylindrical Type Semi-conducting Glaze Porcelain Insulators
- Evaluation Methods of Contamination Flashover Voltage Performance of Cylindrical Type Semi-conducting Glaze Porcelain Insulators
- Improvement of insulation performance of a porcelain long-rod insulator under contaminated conditions (特集 IWHV 2007 (5th International Workshop on High Voltage Engineering))
- Improvement of Insulation Performance of A Porcelain Long-Rod Insulator under Contaminated Conditions
- Effect of Core Diameter of Cylindrical Polymer Insulators on Contamination Flashover Voltage(Part 2) (特集:平成18年〔電気学会〕電力・エネルギー部門大会)
- Effect of Core Diameter of Cylindrical Polymer Insulators on Contamination Flashover Voltage : Part I