Improving Gas Distribution through Agitator and Gas Sparger Modification in an Autoclave Model
スポンサーリンク
概要
- 論文の詳細を見る
An experimental study of the effect of gas sparger geometry and agitator location on gas distribution in agitated systems is presented. The results have shown that varying the impeller position modified the size of low void fraction zone. The optimum impeller position for achieving a small low voidage zone without changing the flow pattern has been identified. It was found that impeller positions below or above the optimal location have a negative effect on gas dispersion while the sparger geometry did not affect significantly the overall gas distribution. Low void fraction zone could be detected by a void sensor even if not visually observed.
- 社団法人 化学工学会の論文
- 2007-03-01
著者
-
Wu Jie
Csiro Fluids Engineering Laboratory
-
Wu Jie
Csiro Division Of Manufacturing And Infrastructure
-
Zhu Yonggang
Csiro Division Of Manufacturing And Infrastructure
-
Noui-mehidi Mohamed
Csiro Division Of Manufacturing And Infrastructure
関連論文
- Intensification of Mixing
- Improving Gas Distribution through Agitator and Gas Sparger Modification in an Autoclave Model