Analysis of Circuit Operation under ZVS and NON-ZVS Conditions in Phase-Shift Inverter for Induction Heating
スポンサーリンク
概要
- 論文の詳細を見る
This paper presents a detailed analysis of circuit operation under ZVS and NON-ZVS conditions in a full-bridge high-frequency phase-shift control series resonant MOSFET inverter with the load of induction heating. Various modes of circuit operation both under ZVS and NON-ZVS conditions are first analyzed in details. The voltage and current equations of these circuits are then obtained and used for calculation of the waveforms by MATLAB program. The calculated results can lead to the consideration of various circuit parameters that determine ZVS or NON-ZVS operating conditions. The theoretical results are also verified by experimental ones, using a prototype test set rated at 3kW.
- 社団法人 電気学会の論文
- 2006-05-01
著者
-
VIRIYA Pichetjamroen
Dept. of Electrical Engineering, Faculty of Engineering, King Mongkut's Institute of Technology Ladk
-
YONGYUTH Naras
Dept. of Electrical Engineering, Faculty of Engineering, Siam University
-
MATSUSE Kouki
School of Science and Technology, Meiji University
-
Viriya Pichetjamroen
Dept. Of Electrical Engineering Faculty Of Engineering King Mongkut's Institute Of Technology L
-
Matsuse Kouki
School Of Science And Technology Meiji University
-
Yongyuth Naras
Dept. Of Electrical Engineering Faculty Of Engineering Siam University
-
MIKI Ichiro
School of Science and Technology, Meiji University
-
Miki Ichiro
School Of Science And Technology Meiji University
関連論文
- Analysis of Transition Mode from Phase-Shift to Zero Phase-Shift under ZVS and NON-ZVS Operation for Induction Heating Inverter
- Analysis of Circuit Operation under ZVS and NON-ZVS Conditions in Phase-Shift Inverter for Induction Heating