新幹線電車用主変圧器中におけるノーメックス^【○!R】紙の熱的安定性の検証
スポンサーリンク
概要
- 論文の詳細を見る
Nomex® brand paper has been used as wire wrapping insulation material of main transformers of Shinkansen Train Series 100 with silicone oil. After approximately 12-13 years service, 8 transformers of Series 100 were sampled to evaluate degradation of Nomex® brand paper in terms of tensile strength and intrinsic viscosity. All data were compared with initial data. The result of less degradation shows Nomex® has good thermal stability in silicone oil in the main transformer of Shinkansen Train which were used in very severe condition.
- 社団法人 電気学会の論文
- 2006-02-01