Parallel Imaging of Head with a Dedicated Multi-coil on a 0.4T Open MRI
スポンサーリンク
概要
- 論文の詳細を見る
Background: Parallel imaging is widely used for cylindrical magnetic resonance imaging (MRI); however, few studies apply parallel imaging to open MRI. We previously developed a parallel method called “RAPID” (rapid acquisition through a parallel imaging design) for imaging the heart on a 0.7T open MRI apparatus, and we have now developed a RAPID head coil and shading correction algorithm for imaging the brain with a 0.4T open MRI apparatus. Images acquired with RAPID were compared with those acquired using a conventional quadrature-detection (QD) head coil. Materials and Methods: The images were acquired using a dedicated 4-channel RF receiving coil consisting of a solenoid coil and surface coils. For MRI of the brain, we developed 2 methods to acquire the necessary calibration data: a pre-scan method that acquires the calibration data before the main scans and a self-calibration method that acquires the calibration data and imaging data simultaneously. We also modified the algorithm for calculating the shading distribution so that it only uses acquired image data and then corrects the shading. Results: RAPID was applied for T1-weighted, T2-weighted, fluid-attenuation inversion recovery (FLAIR), time-of-flight (TOF), and diffusion-weighted echo-planar (DW-EPI) imaging. The RAPID images had no visible unfolded artifacts or motion artifacts. Images with the same contrast as that with a conventional QD coil were acquired using the RAPID coil and shading correction. Conclusion: These preliminary results show that RAPID can be applied to imaging of the head using a 0.4T open MRI apparatus.
- 日本磁気共鳴医学会の論文
- 2005-09-15
著者
-
TAKAHASHI Tetsuhiko
Research and Development Center, Hitachi Medical Corporation
-
TAKIZAWA Masahiro
Research and Development Center, Hitachi Medical Corporation
-
MOCHIZUKI Hiroyuki
Software Development Division, Hitachi Medical Corporation
-
NONAKA Masayuki
MRI Design Department, Hitachi Medical Corporation
-
TAKEUCHI Hiroyuki
MRI Design Department, Hitachi Medical Corporation
-
Nonaka Masayuki
Mri Design Department Hitachi Medical Corporation
-
SHIMODA Takahide
MRI Design Department, Hitachi Medical Corporation
-
KAWASAKI Shinji
MRI Design Department, Hitachi Medical Corporation
-
TACHIBANA Miki
Application Group, Hitachi Medical Corporation
-
Tachibana Miki
Application Group Hitachi Medical Corporation
-
Mochizuki Hiroyuki
Software Development Division Hitachi Medical Corporation
-
Takahashi Tetsuhiko
Research And Development Center Hitachi Medical Corporation
-
Takeuchi Hiroyuki
Mri Design Department Hitachi Medical Corporation
-
Shimoda Takahide
Mri Design Department Hitachi Medical Corporation
-
Takizawa Masahiro
Research And Development Center Hitachi Medical Corporation
-
Kawasaki Shinji
Mri Design Department Hitachi Medical Corporation
関連論文
- Magnetic Resonance Imaging (MRI) Compatible Ultrasound Therapeutic System
- Utilization of Low-Field MR Scanners
- Cardiac Cine Parallel Imaging on a 0.7T Open System
- Parallel Imaging of Head with a Dedicated Multi-coil on a 0.4T Open MRI