Simplified Dosimetry for Human Exposure to Non-uniform ELF Magnetic Field
スポンサーリンク
概要
- 論文の詳細を見る
Regarding recent concerns on the health effects of ELF (extremely low frequency) magnetic fields, compliance testing in accordance with guidelines in highly non-uniform magnetic field has been a critical issue. In these cases, when the measured maximum magnetic fields on the surface of the human body exceed the reference level, the basic restriction should be investigated in a different way. However, this requires numerical calculation of the induced current or electric field, which is not readily achievable. Therefore, a simplified method for investigation of the conformity with a guideline, particularly one applicable to practical situations, is strongly required. In this paper, a new simplified method that can be used to estimate the maximum induced current from magnetic field measurements in practical complex situations was proposed. This method is based on the reduction rate of the magnetic field within a spherical model. The relationship between the reduction rate of magnetic field and the rate of maximum induced current to that of uniform field exposure was approximated using a simple regression curve. The previously proposed method based on averaging of the magnetic field over a certain area was also investigated. The results obtained in the study have practical values for assessing compliance with guidelines.
- 社団法人 電気学会の論文
- 2005-07-01
著者
-
Kawamoto Tadashi
Central Research Institute Of Electric Power Industry
-
YAMAZAKI Kenichi
Central Research Institute of Electric Power Industry
-
FUJINAMI Hideo
Central Research Institute of Electric Power Industry
-
Shigemitsu Tsukasa
Central Research Institute Of Electric Power Industry
関連論文
- Study on induced voltages on an aerial wire due to a current flowing through a grounding grid
- Study of the Quantitative Estimation Method of V-t Characteristics for Nonstandard Lightning Impulse in High-Pressure SF_6 under Quasi-Uniform Field Gap : Application of the Equal Area Criterion by the Square Impulse
- A Review of Studies on the Electric Field and the Current Induced in a Human Body Exposed to Electromagnetic Fields
- Simplified Dosimetry for Human Exposure to Non-uniform ELF Magnetic Field