Effect of Cross Section Shape of Metal Strengthener on Stress Distribution in Acrylic Denture Bases
スポンサーリンク
概要
- 論文の詳細を見る
Purpose : The purpose of this study was to investigate the influence of the cross section shape of a metal strengthener on stress distribution and deflection in acrylic denture bases under loading.Materials and Methods : Thirteen 3-D finite element models of acrylic palatal straps with embedded metal strengtheners of different section shapes (square, rectangle, inverted concave, concave, inverted convex, convex, inverted triangle, triangle, flat top half round, flat bottom half round, inverted horseshoe, horseshoe, and round) having an equal area size were created. The thickness and anterior-posterior width of each strap were 2 mm and 11.2 mm, respectively. One end of each strap was fixed on the ridge, and the median line on the deepest palatal vault of each model was fixed vertically. A vertical or 30 degree distally oblique force of 10 N was loaded on the other end of each strap.Results : The straps with the triangular and square cross section-shaped strengtheners had lower maximum stresses and deflections, while higher values were found in the straps with the round, half round and horseshoe section strengtheners. The straps with the round and half round section strengtheners demonstrated sharp stress concentrations at the interface between the metal and the acrylic denture base under oblique loads.Conclusion : The use of triangular or square section-shaped metal strengtheners effectively minimized both the maximum stress in the acrylic denture base and deflection of the saddle.
- 日本補綴歯科学会の論文
著者
-
Ikeda Tomoyuki
Removable Prosthodontics Department Of Masticatory Function Rehabilitation Division Of Oral Health S
-
SHIMIZU Hajime
Removable Prosthodontics, Department of Masticatory Function Rehabilitation, Division of Oral Health
-
WAKABAYASHI Noriyuki
Removable Prosthodontics, Department of Masticatory Function Rehabilitation, Division of Oral Health
-
OHYAMA Takashi
Removable Prosthodontics, Department of Masticatory Function Rehabilitation, Division of Oral Health
-
Wakabayashi Noriyuki
Removable Prosthodontics Department Of Masticatory Function Rehabilitation Division Of Oral Health S
-
Wakabayashi Noriyuki
Removable Prosthodontics Department Of Masticatory Function Rehabilitation Division Of Oral Health S
-
Ohyama Takashi
Removable Prosthodontics Department Of Masticatory Function Rehabilitation Division Of Oral Health S
-
Wakabayashi Noriyuki
Removable Partial Prosthodontics Department Of Masticatory Function Rehabilitation Division Of Oral
-
Shimizu Hajime
Removable Prosthodontics Department Of Masticatory Function Rehabilitation Division Of Oral Health S
関連論文
- Effect of Cross Section Shape of Metal Strengthener on Stress Distribution in Acrylic Denture Bases
- Dynamic retentive force of a mandibular unilateral removable partial denture framework with a back-action clasp
- Effect of bending on the mechanical properties of gold wrought-wire clasps : a non-linear finite element analysis
- Effect of reactive adhesives on the tensile bond strength of polyvinyl siloxane impression materials to methyl methacrylate tray material
- Reinforcement effects of fiberglass on telescopic dentures using a three-dimensional finite element analysis and fracture test
- Masticatory function after unilateral distal extension removable partial denture treatment: intra-individual comparison with opposite dentulous side
- Influence of Dimensions of Ti-6Al-7Nb and Co-Cr Lingual Bars on Stress Peak in Underlying Oral Mucosa : An FEM Study
- Reproducibility of Interocclusal Recording for Mandibular Removable Partial Denture in Bilateral Distal Extension Cases
- Patients' preference for acrylic resin major connector analogues formulated for titanium alloy removable partial dentures
- Electromyographic evaluation of masticatory function in denture wearers in related to existing occlusal support
- Bilinear elastic property of the periodontal ligament for simulation using a finite element mandible model