Design and Structural Analysis of Support Structure for ITER Vacuum Vessel
スポンサーリンク
概要
- 論文の詳細を見る
The International Thermonuclear Experimental Reactor (ITER) vacuum vessel (VV) is a safety component confining radioactive materials such as tritium and activated dust. An independent VV support structure with multiple flexible plates located at the bottom of VV lower port is proposed as a new concept, which is deferent from the current design, i.e., the VV support is directly connected to the toroidal coils (TF coils). This independent concept has two advantages comparing to the current one: (1) thermal load due to the temperature deference between VV and TF coils becomes lower and (2) the TF coils are categorized as non-safety components because of its independence from VV. Stress Analyses have been performed to assess the integrity of the VV support structure using a precisely modeled VV structure. As a result, (1) the maximum displacement of the VV corresponding to the relative displacement between VV and TF coils is found to be 15 mm, much less than the current design clearance of 100 mm, and (2) the stresses of the whole VV system including VV support are estimated to be less than the allowable ones defined by ASME Section III Subsection NF, respectively. Based on these assessments, the feasibility of the proposed independent VV support has been verified as a VV support.
- 社団法人 日本原子力学会の論文
- 2004-12-25
著者
-
Takeda Nobukazu
Japan Atomic Energy Research Institute
-
OHMORI Junji
Japan Atomic Energy Research Institute
-
NAKAHIRA Masataka
Japan Atomic Energy Research Institute
-
SHIBANUMA Kiyoshi
Japan Atomic Energy Research Institute
-
Ohmori J
Japan Atomic Energy Res. Inst. Ibaraki Jpn
-
OHMORI Junji
Japan Atomic Energy Agency
関連論文
- Design and Structural Analysis of Support Structure for ITER Vacuum Vessel
- Technical Code Issues of ITER Vacuum Vessel and Their Resolutions
- Structural Safety Assessment of a Tokamak-Type Fusion Facility for a Through Crack to Cause Cooling Water Leakage and Plasma Disruption