Leak Detection in the Primary Reactor Coolant Piping of Nuclear Power Plant by Applying Beam-Microphone Technology
スポンサーリンク
概要
- 論文の詳細を見る
A microphone leak detection method was applied to the inlet piping of the ATR-prototype reactor, Fugen. Statistical analysis results showed that the cross-correlation method provided the effective results for detection of a small leakage. However, such a technique has limited application due to significant distortion of the signals on the reactor site. As one of the alternative methods, the beam-microphone provides necessary spatial selectivity and its performance is less affected by signal distortion. A prototype of the beam-microphone was developed and then tested at the O-arai Engineering Center of the Japan Nuclear Cycle Development Institute (JNC). On-site testing of the beam-microphone was carried out in the inlet piping room of an RBMK reactor of the Leningrad Nuclear Power Plant (LNPP) in Russia. A leak sound imitator was used to simulate the leakage sound under the leakage flow condition of 1–3 gpm (0.23–0.7 m3/h). Analysis showed that signal distortion does not seriously affect the performance of this method, and that sound reflection may result in the appearance of ghost sound sources. The test results showed that the influences of sound reflection and background noise were smaller at the high frequencies where the leakage location could be estimated with an angular accuracy of 5° which is within the range of localization accuracy required for the leak detection system.
- 一般社団法人 日本原子力学会の論文
- 2004-03-25
著者
-
Kanazawa Junichi
Musashino Laboratory Of Vibration Damping
-
Shimanskiy Sergey
Research And Development Institute Of Power Engineering (rdipe)
-
Kasai Yoshimitsu
Pesco Co. Ltd.
-
NAOI Yosuke
Japan Nuclear Cycle Development Institute (JNC)
-
KANAZAWA Junihci
Musashino Laboratory of Vibration Damping
関連論文
- Leak Detection in the Primary Reactor Coolant Piping of Nuclear Power Plant by Applying Beam-Microphone Technology
- ICONE11-36274 LEAK DETECTION IN THE PRIMARY REACTOR COOLANT PIPING OF NPP BY APPLYING A BEAM-MICROPHONE
- Development of Acoustic Leak Detection and Localization Methods for Inlet Piping of Fugen Nuclear Power Plant