Suitability testing of commercial solid-phase extraction sorbents for sample clean-up in systematic toxicological analysis using liquid chromatograph-(tandem) mass spectrometry
スポンサーリンク
概要
- 論文の詳細を見る
- 2003-06-05
著者
-
Van Peteghem
Laboratory Of Food Analysis Faculty Of Pharmaceutical Sciences Ghent University
-
Van Peteghem
Laboratory Of Toxicology Ghent University
-
VAN BOCXLAER
Laboratory of Medical Biochemistry and Clinical Analysis, Ghent University
-
Van Bocxlaer
Laboratory Of Medical Biochemistry And Clinical Analysis Ghent University
-
Van Bocxlaer
Laboratorium Voor Toxicologie Universiteit Gent
-
DECAESTECKER N.
Laboratory of Medical Biochemistry and Clinical Analysis, Ghent University
-
COOPMAN Evelien
Laboratory of Medical Biochemistry and Clinical Analysis, Ghent University
-
Decaestecker N.
Laboratory Of Medical Biochemistry And Clinical Analysis Ghent University
-
Coopman Evelien
Laboratory Of Medical Biochemistry And Clinical Analysis Ghent University
関連論文
- Liquid chromatographic separation of doxycycline and 4-epidoxycycline in a tissue depletion study of doxycycline in turkeys
- Detection of synthetic glucocorticoid residues in cattle tissue and hair samples after a single dose administration using LC-MS/MS
- Use of metal chelate affinity chromatography and membrane-based ion-exchange as clean-up procedure for trace residue analysis of tetracyclines in animal tissues and egg
- Pharmacokinetics of fluoroquinolones in critical care patients : A bio-analytical HPLC method for the simultaneous quantification of ofloxacin, ciprofloxacin and moxifloxacin in human plasma
- Joint GC-MS and LC-MS platforms for comprehensive plant metabolomics : Repeatability and sample pre-treatment
- LC-MS metabolic profiling of Arabidopsis thaliana plant leaves and cell cultures : Optimization of pre-LC-MS procedure parameters
- Confirmation of ofloxacin precipitation in corneal deposits by microbore liquid chromatography-quadrupole time-of-flight tandem mass spectrometry
- Potential of high-performance liquid chromatography with photodiode array detection in forensic toxicology
- Quantitative determination of glycopyrrolate in human plasma by liquid chromatography-electrospray ionization mass spectrometry : The use of a volatile ion-pairing agent during both liquid-liquid extraction and liquid chromatography
- Suitability testing of commercial solid-phase extraction sorbents for sample clean-up in systematic toxicological analysis using liquid chromatograph-(tandem) mass spectrometry