ZVS Bridge Leg and ZCS Bridge Leg DC-DC Converter with Tapped Inductor Filter
スポンサーリンク
概要
- 論文の詳細を見る
In this paper, a novel full-bridge soft-switching phase-shifted PWM DC-DC power converter circuit is presented. A tapped inductor filter is implemented in the proposed converter topology to achieve soft switching commutation for the active power switches under wide load variation range, to minimize circulating current without using additional resonant circuit and/or auxiliary switching devices. The effectiveness of the proposed soft-switching DC-DC power converter is verified in experiment with 2kW-100kHz breadboard circuit using IGBTs.
- 社団法人 電気学会の論文
- 2003-09-01
著者
-
NAKAOKA Mutsuo
Division of Electrical and Electronics Systems Engineering, The Graduate School of Science and Engin
-
Hamada Satoshi
Division Of Cardiovascular Surgery Department Of Surgery School Of Medicine Faculty Of Medicine Toho
-
Moisseev Serguei
Division Of Systems Engineering The Graduate School Of Science And Engineering Yamaguchi University
-
Hamada Satoshi
Division Of Systems Engineering The Graduate School Of Science And Engineering Yamaguchi University
-
Nakaoka Mutsuo
Division Of Systems Engineering The Graduate School Of Science And Engineering Yamaguchi University
関連論文
- PI Closed-Loop Feedback Terminal Voltage Control Scheme based on Static VAR Compensator for Three-Phase Self-Excited Induction Generator
- Study of coronary artery bypass using the PAS-Port device : assessment by multidetector computed tomography
- Usefulness of perioperative blood glucose control in patients undergoing off-pump coronary artery bypass grafting
- Limitations of Retrograde Continuous Tepid Blood Cardioplegia for Myocardial Remodeling
- Assessment of On-Pump Beating Coronary Artery Bypass Surgery Performed after Introduction of Off-Pump Approach
- ZVS Bridge Leg and ZCS Bridge Leg DC-DC Converter with Tapped Inductor Filter
- An Aortic Root Pseudoaneurysm That Developed after Implantation of a Rectus Abdominis Muscle Flap to Treat an MRSA Mediastinitis : A Case Report
- Successful Surgical Repair of an Infectious Thoracic Aortic Pseudoaneurysm Accompanied by Aortobronchopulmonary Fistula and Advanced Hepatic Dysfunction without Assisted Circulation
- Stent Graft Implantation Combined with Coil Embolization and External-Internal Iliac Artery Bypass Surgery : Report of a Case
- Static VAR Compensator-Based Voltage Regulation for Variable-Speed Prime Mover Coupled Single-Phase Self-Excited Induction Generator
- High-Frequency Isolated Soft-Switching Phase-Shift PWM DC-DC Power Converter Using Tapped Inductor Filter(DC/DC Converters)(the 25th International Telecommunications Energy Conference(INTELEC'03))
- Fontan Conversion with Novel Direct Ablation After Childbirth : Report of a Case