モールド変圧器の光診断法による熱劣化診断技術
スポンサーリンク
概要
- 論文の詳細を見る
The application possibility of an optical diagnosis was examined as simple and non-destructive technique for diagnosing the degree of thermal deterioration of molded transformers. The optical diagnosis is the technology of estimating the degree of the thermal deterioration of organic insulating resins from the reflective absorbance difference between two wavelengths containing near-infrared light, and life prediction is also possible by using chemical kinetics. First, as a result of investigating the correlation with the glass transition temperature related to the degree of the thermal deterioration of epoxy resins obtained from the dynamic viscoelastic characteristics and the reflective absorbance difference which was a diagnostic parameter, with the correlation coefficient of 0.9 or more it was theoretically judged that an optical diagnosis was applicable. Then, the diagnostic master curve was obtained from the accelerated thermal degradation examination using model samples. Next, the optical fiber cable and the probe of a portable optical diagnostic apparatus were improved using bundle fibers. As a result of evaluating six sets of operating transformers using the improved diagnostic apparatus, it has confirmed that the residual life could be estimated.
- 社団法人 電気学会の論文
- 2003-07-01
著者
-
竹澤 由高
(株)日立製作所日立研究所 電子材料研究部高機能高分子ユニット
-
片桐 純一
(株)日立製作所 材料研究所
-
竹澤 由高
日立化成工業(株)先端材料開発研究所
-
竹澤 由高
(株)日立製作所 日立研究所
-
竹沢 由高
日立
-
山中 功治
(株)日立産機システム 中条事業所
関連論文
- 高熱伝導成形材の開発と放熱特性
- 高熱伝導絶縁樹脂
- 高熱伝導成形材の開発と放熱特性
- 放熱性の優れた高次構造制御エポキシ樹脂の開発
- 樹脂自体の熱伝導率を高めた高次構造制御エポキシ樹脂
- 鉱油含浸絶縁紙の圧縮特性の時間および温度依存性
- 油入変圧器用絶縁紙の光による劣化診断技術
- 光診断による変圧器絶縁油の劣化度評価
- 光ファイバーセンサを用いた絶縁材料の非破壊熱劣化診断法の開発
- 原子力用低圧ケーブル経年劣化への光診断法適用
- 光による柱上変圧器の間接劣化診断装置の開発
- モールド変圧器の光診断法による熱劣化診断技術
- 光による中型変圧器の劣化診断法の検討
- ナノ高次構造制御エポキシ樹脂
- 柱上変圧器の間接劣化診断装置の開発
- 高熱伝導性エポキシ樹脂の高次構造
- 省エネルギー化に対応した変圧器の動向