Influence of total knee replacement (TKR) design on screw-home movement : Comparison of five designs for total knee replacement prostheses
スポンサーリンク
概要
- 論文の詳細を見る
- 1996-09-01
著者
-
KOGA Yoshio
Niigata Kobari Hospital
-
BECHTOLD Joan
Hennepin County Medical Center
-
Bechtold Joan
^3departments Of Orthopaedic Surgery
-
Ishii Yoshinori
Departments Of ^1 Orthopaedic Surgery
-
TERAJIMA Kazuhiro
Department of Mechanical Engineering Niigata University
-
KOGA Yoshio
Departments of ^1 Orthopaedic Surgery
-
TERAJIMA KAZUHIRO
Niigata University Mechanical Engineering
-
TAKAHASHI HIDEKI
Niigata University School of Medicine
-
Ishii Yoshinori
Department Of Orthopaedic Surgery
-
Koga Y
Kyusyu Univ. Fukuoka Jpn
-
Terajima Kazuhiro
Mechanical Engineering Niigata University
-
Koga Y
Niigata Kobari Hospital Jpn
-
Takahashi H
Niigata Univ. Niigata Jpn
-
Takahashi Hideki
Niigata University Of Health And Welfare
関連論文
- Accuracy Verification of Image-Matching in a Setting Method for the Stem during Total Hip Arthroplasty
- 人工膝関節置換術その歴史と現況
- Numerical Analysis of Pressure on Cup Surface after THA
- Joint Proprioception in the Elderly With and Without Hip Fracture
- Gait analysis after total knee arthroplasty. Comparison of posterior cruciate retention and substitution
- In Vivo Three-Dimensional Kinematics of the Human Knee
- Influence of total knee replacement (TKR) design on screw-home movement : Comparison of five designs for total knee replacement prostheses
- Is bone density in the distal femur affected by use of cement and by femoral component design in total knee arthroplasty?
- Independent Predictors of Knee Osteoarthritis in an Elderly Japanese Population : A Multivariate Analysis
- Impact Response Analysis of Patella-Patellar Tendon-Tibial Tuberosity Complex(Impact 2)
- Multiple osteochondroses of bilateral knee joints
- Development of a physiological knee motion simulator
- CORRELATION OF SOLUBILITIES OF FATTY ACIDS AND HIGHER ALCOHOLS IN SUPERCRITICAL CARBON DIOXIDE WITH COSOLVENT USING VIRIAL EQUATION OF STATE
- CORRELATION OF VAPOR-LIQUID EQUILIBRIA FOR CARBON DIOXIDE+HIGH-BOILING COMPONENT SYSTEMS USING SIMPLIFIED PERTURBED HARD CHAIN THEORY
- MONTE CARLO CALCULATION OF SOLUBILITIES OF HIGH-BOILING COMPONENT IN SUPERCRITICAL CARBON DIOXIDE AND SOLUBILITY ENHANCEMENTS BY ENTRAINER
- CORRELATION OF SOLUBILITIES OF HIGH-BOILING COMPONENTS IN SUPERCRITICAL CARBON DIOXIDE USING A SOLUTION MODEL
- Three-dimensional knee motion before and after high tibial osteotomy for medial knee osteoarthritis
- Relationship between radiological knee osteoarthritis and biochemical markers of cartilage and bone degradation (urine CTX-II and NTX-I) : the Matsudai Knee Osteoarthritis Survey
- High tibial osteotomy using two threaded pins and figure-of-eight wiring fixation for medial knee osteoarthritis : 14 to 24 years follow-up results
- The effect of geometry of the tibial polyethylene insert on the tibiofemoral contact kinematics in Advance Medial Pivot total knee arthroplasty
- Three-dimensional lower extremity alignment in the weight-bearing standing position in healthy elderly subjects