Best Estimated Method to Determine Energy Redistribution Factor for LOCA Analysis
スポンサーリンク
概要
- 論文の詳細を見る
The new method introduces the response that is independent of the burn-up and rod-power distributions, and makes Energy Redistribution Factor (ERF) calculated easily and exactly with the response. The new method also includes the burn-up effect, which means that the maximum pin power is decreased as the core is burned up, to the ERF and uses the 5×5-assembly array for the long gamma ray’s mean free path. The rod power distribution of the array in the method is calculated by the core design code. The new method was applied to the several cycles of Korean Standard Nuclear Plant. The results showed that the new method was able to reduce the excessive conservatism in the ERF for LOCA than the current method where the cycle maximum ERF is used for calculating the Peak Clad Temperature.
- 社団法人 日本原子力学会の論文
- 2001-06-25
著者
-
Do Man
Kepco Nuclear Fuel Co. Ltd. (knfc)
-
CHOI Taeyoung
KEPCO Nuclear Fuel Co., Ltd. (KNFC)
-
PARK Chan
KEPCO Nuclear Fuel Co., Ltd. (KNFC)
-
LEE Chang
KEPCO Nuclear Fuel Co., Ltd. (KNFC)
-
Park Chan
Kepco Nuclear Fuel Co. Ltd. (knfc)
-
Choi Taeyoung
Kepco Nuclear Fuel Co. Ltd. (knfc)
-
Lee Chang
Kepco Nuclear Fuel Co. Ltd. (knfc)