Development of Simplified Wave-type Vane in BWR Steam Dryer and Assessment of Vane Droplet Removal Characteristics
スポンサーリンク
概要
- 論文の詳細を見る
Air-water experiments were performed for the BWR steam dryer in order to elucidate droplet removal characteristics of the vane. Based on the results, a simplified vane was developed and its droplet removal characteristics were confirmed by air-water experiments using a whole dryer model. Phase-Doppler anemometer was used to measure droplet diameter distributions. In the experiments of the current vane with four-wave stages and 120° bend angle, almost all of the droplets were found to be trapped in the first and second vane stages. For the air velocity of 3.1 m/s, 90% of the inlet droplets were trapped there and 4% were trapped in the third and fourth stages, resulting in 6% being carried over. Sauter mean diameters at the exit were 6 and 5 μm while at the inlet they were 71 and 64 μm for the respective air velocities of 1 and 3 m/s. Based on the Weber number evaluation, the possible mechanism for the fine droplet generation was considered to be the breakup of droplets due to impingement on the liquid film formed in the vane surface. From the above results, the simplified vane with two-wave stages was developed. In order to remove fine droplets, the bend angle of the vane was reduced to 90°, in which a larger inertia force is exerted on finer droplets generated by breakup. Experiments for the whole dryer model showed that the developed vane could achieve the same droplet removal characteristics as the current vane without increasing the pressure drop of the dryer. A design having ten dryer bank rows and 1.2 m height, which is 0.8 m shorter than the current dryer, is possible for the dryer using the new simplified vane.
- 社団法人 日本原子力学会の論文
- 1999-05-25
著者
-
Murase Michio
Power & Industrial Systems R&d Division Hitachi Ltd.
-
Murase Michio
Power & Industrial Systems R&d Laboratory Hitachi Ltd.
-
Murase Michio
Power & Industrial Systems R & D Division Hitachi Ltd.
-
Nagase Makoto
Power And Industrial Systems R&d Laboratory Hitachi Ltd.
-
NAKAO Toshitsugu
Power & Industrial Systems R&D Laboratory, Hitachi Ltd.
-
AOYAMA Goro
Power & Industrial Systems R&D Laboratory, Hitachi Ltd.
-
Aoyama Goro
Power & Industrial Systems R&d Laboratory Hitachi Ltd.
-
Nakao Toshitsugu
Power & Industrial Systems R&d Laboratory Hitachi Ltd.
-
Nagase Makoto
Power & Industrial Systems R&d Laboratory Hitachi Ltd.
関連論文
- Measurement of Condensation Heat Transfer Coefficient inside a Vertical Tube in the Presence of Noncondensable Gas
- Evaporation and Condensation Heat Transfer in a Suppression Chamber of the Water Wall Type Passive Containment Cooling System
- Effect of a Divided Wetwell on Heat Removal Capability of the Water Wall Type Passive Containment Cooling System
- Development of Simplified Wave-type Vane in BWR Steam Dryer and Assessment of Vane Droplet Removal Characteristics
- Low Corrosive Chemical Decontamination Method Using pH Control, (II) Decomposition of Reducing Agent by Using Catalyst with Hydrogen Peroxide
- Low Corrosive Chemical Decontamination Method Using pH Control, (I) Basic System
- Droplet Behavior Analyses in the BWR Dryer and Separator
- Investigation of Cobalt Deposition Behavior with Zinc Injection on Stainless Steel under BWR Conditions