Prediction of Liquid Film Dryout in Two-Phase Annular-Mist Flow in a Uniformly Heated Narrow Tube Development of Analytical Method under BWR Conditions
スポンサーリンク
概要
- 論文の詳細を見る
A method was developed based on the conservation lows to predict critical heat flux (CHF) causing liquid film dryout in two-phase annular-mist flow in a uniformly heated narrow tube under BWR conditions. The applicable range of the method is within the pressure of 3-9MPa, mass flux of 500-2, 000kg/m<SUP>2</SUP>•s, heat flux of 0.33-2.0MW/m<SUP>2</SUP> and boiling length-to-tube diameter ratio of 200-800.<BR>The two-phase annular-mist flow was modeled with the three-fluid streams with liquid film, entrained droplets and gas flow. Governing equations of the method are mass continuity and energy conservation on the three-fluid streams. Constitutive equations on the mass transfer which consist of the entrainment fraction at equilibrium and the mass transfer coefficient were newly proposed in this study.<BR>Confirmation of the present method were performed in comparison with the available film flow measurements and various CHF data from experiments in uniformly heated narrow tubes under high pressure steam-water conditions. In the heat flux range (q"<2MW/m<SUP>2</SUP>) practical for a BWR, agreement of the present method with CHF data was obtained as, (Averaged ratio)±(Standard deviation)=0.984+0.077, which was shown to be the same or better agreement than the widely-used CHF correlations.
- 社団法人 日本原子力学会の論文
- 1998-09-25
著者
-
Kaminaga Fumito
Ibaraki University
-
UTSUNO Hideaki
Hitachi Works, Hitachi, Ltd.
-
Utsuno H
Hitachi Works Hitachi Ltd.
-
Utsuno Hideaki
Hitachi Works Hitachi Ltd.
関連論文
- Estimation of Generated Volume of Radiolytic Gas Voids during Prompt Criticality with 10% Enriched Uranium Nitrate Solution in TRACY
- Prediction of Liquid Film Dryout in Two-Phase Annular-Mist Flow in a Uniformly Heated Narrow Tube Development of Analytical Method under BWR Conditions
- New Estimation Method for Void Reactivity Coefficient Using the TRACY Transient Data
- Best Estimate BWR Transient Analysis with TRACG Assessment using Data from BWR Startup Tests and LOCA Integral Tests
- Measuring Method for ABWR Core Flow Rate.