Effect of Axial Dispersion on the Evaluation of Enantiomeric Ratio by a Fixed-Bed Reactor
スポンサーリンク
概要
- 論文の詳細を見る
An earlier investigation has presented a novel procedure in the chromatographic reactor, capable of efficiently determining the enantioselectivity of the enzyme for a biocatalyzed process. In this work, a mathematical model including the effect of axial dispersion is formulated to describe the transient behavior of the fixed-bed used to evaluate the enantiomeric ratio. A valuable relationship among the enantioselectivity, Pèclet number, and transient responses at the exit of reactor is also established through the theoretical analysis. In addition, a relation is proposed to evaluate the significance of axial dispersion in the fixed-bed, allowing us to apply this criterion to assess the necessity of further studying the Pèclet number.
- Society of Chemical Engineersの論文
- 1998-12-01
著者
関連論文
- MN-P4 A novel approach to fluorophore-free luminescent hybrid silica gels(Section X Micro/Nano Technology for Analysis and Cell Manipulation)
- Enhancement of Enantioselectivity by Altering Alcohol Concentration for Esterification in Supercritical CO_2
- Effect of Axial Dispersion on the Evaluation of Enantiomeric Ratio by a Fixed-Bed Reactor
- Fast calculation of elution curves of a slurry adsorber with nonlinear kinetics.
- Simulation of nonlinear fixed-bed adsorbers by orthogonal collocation with the aid of fast Fourier transform.