Multichannel Biosensing and Stimulation LSI Chip Using 0.18 μm Complementary Metal–Oxide–Semiconductor Technology
スポンサーリンク
概要
- 論文の詳細を見る
We designed 8-channel preamplifiers and multisite stimulation circuits on a $2.5 \times 1.4$ mm2 chip using a 0.18 μm complementary metal–oxide–semiconductor (CMOS) process for a microelectrode array measurement system. The size of a 1-channel preamplifier including a DC store/adder circuit is $930 \times 120$ μm2. An 8-channel programmable stimulator was integrated on the same die. The preamplifier circuits can amplify a small neural signal with a low noise and a low power consumption (2 mW/ch) using a chopper operation. The stimulation circuits can apply a voltage of $\pm 700$ mV to any channel and with any timing using serial digital data control. The performance of the biphasic stimulation waveform generated by the designed LSI chip is the same as that generated with a conventional stimulation system. These functions were confirmed by connecting the LSI chip to a conventional measurement system. The system miniaturization achieved using the custom LSI chip will offer great advantages in terms of future brain machine interface applications.
- 2010-04-25
著者
-
TORIMITSU Keiichi
NTT Basic Research Laboratories
-
Masaya Yamaguchi
Dept. of Electronics and Electrical Engineering, Keio University, 3-14-1 Hiyoshi, Kohoku-ku, Yokohama 223-8522, Japan
-
Yamaguchi Masaya
Dept. of Electronics and Electrical Engineering, Keio University, 3-14-1 Hiyoshi, Kohoku-ku, Yokohama 223-8522, Japan
-
Shimada Akiyoshi
NTT Basic Research Laboratories, NTT Corporation, 3-1 Morinosato-Wakamiya, Atsugi, Kanagawa 243-0198, Japan
-
Nobuhiko Nakano
Dept. of Electronics and Electrical Engineering, Keio University, 3-14-1 Hiyoshi, Kohoku-ku, Yokohama 223-8522, Japan
-
SHIMADA Akiyoshi
NTT Basic Research Laboratories
-
Akiyoshi Shimada
NTT Basic Research Laboratories, NTT Corporation, 3-1 Morinosato-Wakamiya, Atsugi, Kanagawa 243-0198, Japan
関連論文
- Effect of UV/Ozone Treatment on Nanogap Electrodes for Molecular Devices
- Effect of UV/ozone Treatment of Nanogap Electrodes for Molecular Devices
- A Field-Effect Transistor with a Deposited Graphite Thin Film
- Electrochemical Monitoring of Glutamate Release at Multiple Positions in a Rat Hippocampal Slice
- Continuous Measurement of Glutamate and Hydrogen Peroxide Using a Microfabricated Biosensor for Studying the Neurotoxicity of Tributyltin
- Microfabricated On-Line Sensor for Continuous Monitoring of L-Glutamate
- DIRECT OBSERVATIONS OF SYNAPTIC GLUTAMATE RELEASE MODULATED BY GABA AND NEUROTROPHINS IN CULTURED RAT CORTICAL NEURONS
- Effect of External pH on the Cytoplasmic and Vacuolar pHs in Mung Bean Root-Tip Cells : A ^P Nuclear Magnetic Resonance Study
- Visualization of Single Membrane Protein Structure in Stretched Lipid Bilayer Suspended over Nanowells
- Self-spreading Behavior of Supported Lipid Bilayer through Single Sub-100-nm Gap
- Observation and Manipulation of Nanostructures Formed by Rigid Rodlike Polymers
- A New Screw-Sense Switchable Polysilylene with Quantized and Superposed Helicities
- Electrical Characterization of Terphenyl-Based Molecular Devices
- Molecular-Mediated Single-Electron Devices Operating at Room Temperature
- Atomic Force Microscopy Observation of Membrane Proteins Suspended over Carbon Nanotube Network
- Confinement of Fluorescent Probes in Microwells on Si Substrates by Sealing with Lipid Bilayers
- 1P558 Real-time Imaging of DNA-Streptavidin Complex Formation in Solution using a High-Speed Atomic Force Microscope(26. Single molecule biophysics,Poster Session,Abstract,Meeting Program of EABS & BSJ 2006)
- Effect of UV/Ozone Treatment on Nanogap Electrodes for Molecular Devices
- Effect of Ca2+ on Vesicle Fusion on Solid Surface: An In vitro Model of Protein-Accelerated Vesicle Fusion
- 3A1334 シリコン基板上微小井戸アレイによるαヘモリシン・チャネルのカルシウムイオン透過計測(3A 生体膜・人工膜4(輸送、情報伝達),日本生物物理学会第49回年会)
- Examination of Ion Channel Protein Orientation in Supported Lipid Bilayers
- Observation and Manipulation of Nanostructures Formed by Rigid Rodlike Polymers
- Multichannel Biosensing and Stimulation LSI Chip Using 0.18 μm Complementary Metal–Oxide–Semiconductor Technology
- Field-Effect Transistor with Deposited Graphite Thin Film
- 3PT148 架橋脂質二分子膜における秩序液体相/液晶相の分離(日本生物物理学会第50回年会(2012年度))
- Transistor Properties of Novel Organic Conducting Polymers Bearing Tetrathiafulvalene Units in the Backbone
- Electrostatic Control of Artificial Cell Membrane Spreading by Tuning the Thickness of an Electric Double Layer in a Nanogap
- Self-Spreading Supported Lipid Bilayer Passing through Single Nanogap Structure: Effect of Position of Dyes in Lipid Molecules
- リアルタイム過酸化水素イメージング用センサアレイの作製
- Self-Spreading Behavior of Supported Lipid Bilayer through Single Sub-100-nm Gap