Performance of Prototype Hard X-ray Polarimeter Utilizing Compton Scattering
スポンサーリンク
概要
- 論文の詳細を見る
In X-ray astronomy, various kinds of information on stellar objects have been obtained from energy spectrum, time variabilities, and images. Although the observation of polarization is also important, it has not been carried out for 25 years, because of the difficulty of developing a polarimeter with a high sensitivity. Thus, we have been developing a Compton-scattering-type hard X-ray polarimeter sensitive to the energy range from 40 to 300 keV, employing segmented plastic and CsI($\mathit{Tl}$) scintillators mounted on a flat-panel multianode photomutiplier (MAPMT). Constructing the prototype polarimeter and using polarized hard X rays of 80 keV, we carried out basic experiments to investigate the performance of our polarimeter. Moreover, we carried out computer simulations and confirmed that the results obtained by computer simulation are in good agreement with those obtained by experiment. Finally, it was found that the prototype polarimeter can obtain a modulation factor and a detection efficiency of ${\sim}40$ and ${\sim}20$%, respectively.
- 2006-01-15
著者
-
Tokanai Fuyuki
Department Of Physics Yamagata University
-
Nakajima Ryo
Department Of Chemistry And Chemical Biology Gunma University
-
YAMASHITA Yuichiro
Department of Atomic Science and Nuclear Engineering, Faculty of Engineering, Hokkaido University
-
Gunji Shuichi
Department Of Physics Faculty Of Science Yamagata University
-
Suzuki Toshiji
Department of Physics, Yamagata University, Yamagata 990-8560, Japan
-
Suzuki Kazufumi
Department of Physics, Yamagata University, Yamagata 990-8560, Japan
-
Sakurai Hirohisa
Department of Physics, Yamagata University, Yamagata 990-8560, Japan
-
Takashima Ken
ISAS, Sagamihara, Kanagawa 229-8510, Japan
-
Kobayashi Yoshihito
ISAS, Sagamihara, Kanagawa 229-8510, Japan
-
Tamura Kenichi
ISAS, Sagamihara, Kanagawa 229-8510, Japan
-
Kishimoto Shunji
KEK-PF, Tsukuba, Ibaraki 305-0801, Japan
-
Yamashita Yuichiro
Department of Physics, Yamagata University, Yamagata 990-8560, Japan
-
Gunji Shuichi
Department of Physics, Yamagata University, Yamagata 990-8560, Japan
-
Nakajima Ryo
Department of Physics, Yamagata University, Yamagata 990-8560, Japan
関連論文
- Comparison of SPACE and 3D TSE MRCP at 1.5T Focusing on Difference in Echo Spacing
- Decay Properties of ^Bh and ^Db Produced in the ^Cm + ^Na Reaction
- PJ-341 Image Quality of Coronary Computed Tomographic Angiography without Beta-blocker Administration for Heart Transplant Recipients(PJ058,CT/MRI (Coronary/Vascular) 1 (I),Poster Session (Japanese),The 73rd Annual Scientific Meeting of The Japanese Circu
- Observation of Second Decay Chain from ^113
- Experiment on Synthesis of an Isotope ^112 by ^Pb+^Zn Reaction(Nuclear physics)
- Laser-induced line patterning of nonlinear optical β'-Sm[x]Gd[2-x](MoO4)3 molybdate crystals in glass (特集 光機能材料)
- Imaging findings from a case of bilharziasis in a patient with gross hematuria of several years' duration
- Malignant tumor, of the gastrointestinal stromal tumor type, in the greater omentum
- Acute Effects of Distal Pancreatectomy on Portal and Peripheral Blood Insulin Concentrations in Patients Undergoing Total Gastrectomy
- Prospective Electrocardiogram-Gated Axial 64-Detector Computed Tomographic Angiography vs Retrospective Gated Helical Technique to Assess Coronary Artery Bypass Graft Anastomosis : Comparison of Image Quality and Patient Radiation Dose
- Compression Belt for Navigator-triggered trueFISP Whole-heart Coronary Magnetic Resonance Angiography : Study in Healthy Volunteers
- Frequency of Common Bile Duct Motion Artifacts Caused by Inferior Vena Cava Pulsation on Magnetic Resonance Cholangiopancreatography
- X- Ray/Soft Gamma-Ray Observation of Centaurus A and Its Implication on the Emission Mechanism
- Relaxin Modulates Collagen Type I and Matrix Metalloproteinase-1 Expression by Human Periodontal Ligament Cells
- Theoretical Analysis of Phase Diagrams and Mixing Heats of Systems of Ketone/1-Alcohol
- Photochemistry of π-Complexes of Chlorine Atom with Methyl- and Ethyl-Substituted Benzenes
- Prospective Electrocardiogram-Gated Axial 64-Detector Computed Tomographic Angiography vs Retrospective Gated Helical Technique to Assess Coronary Artery Bypass Graft Anastomosis: : – Comparison of Image Quality and Patient Radiation Dose –
- Gamma-Ray Burst Polarimeter (GAP) aboard the Small Solar Power Sail Demonstrator IKAROS
- Decay Properties of 266Bh and 262Db Produced in the 248Cm + 23Na Reaction
- Performance of Prototype Hard X-ray Polarimeter Utilizing Compton Scattering
- New Result in the Production and Decay of an Isotope, 278113, of the 113th Element
- IL-6 and IL-17 in the Gingival Crevicular Fluid During Orthodontic Root Resorption
- Standardization of image quality across multiple centers by optimization of acquisition and reconstruction parameters with interim FDG-PET/CT for evaluating diffuse large B cell lymphoma