Inverse Analysis of Multiple Cracks Using Magnetic Flux Leakage Considering the Size of Flux Gate Sensor
スポンサーリンク
概要
- 論文の詳細を見る
In this study, multiple cracks on a structural member were detected using the magnetic flux leakage method. The distribution of magnetic flux density was measured using a flux gate sensor. A function that relates the magnetic dipoles and the magnetic flux density measured using the flux gate sensor was improved to capture the average value of the sensor length. The effectiveness of this improvement was verified through a numerical model with two adjacent semi-elliptical surface cracks. Cracks were detected separately using inverse analysis. In contrast, cracks were detected as being connected using the unimproved function.
- 日本AEM学会の論文
日本AEM学会 | 論文
- Characterization of Piezoelectric Fibers with Metal Core (特集 第14回MAGDAコンファレンス)
- 摩擦式電磁クラッチ・ブレーキの鳴き
- MAGIC砥石製作過程の数値解析 : 球形粒子体積分率の粒子分布への影響
- 可搬型ライナックX線源によるポンプ状態監視保全の原理実証(第17回MAGDAコンファレンス)