Objective: Not only the femoral rotational alignment but also the tibial rotational alignment of the total knee arthroplasty (TKA) is considered a significant factor in securing favorable knee joint function. However, for those patients with brittle bones, such as rheumatoid arthritis or elderly women, there are some cases in which we will give priority to bone coverage over rotational alignment. The purpose of this study was to examine the relationship between the tibial anteroposterior (AP) axis and the position of the tibial component that prioritizes bone coverage.Methods: In total, 157 preoperative knees of 106 patients with varus osteoarthritis indicated for primary TKA were included in the study. Two knees in which it was not possible to identify the posterior cruciate ligament (PCL) insertion were excluded from the examination. Radiographic grading was performed by using the Kellgren-Lawrence (K-L) criteria (grade 3, n=59; grade 4, n=96). We used three-dimensional preoperative planning software (Athena, Soft Cube) to simulate the tibial component fixations in the assumed cases in which the bone coverage was maximized, and we compared them with Akagi's tibial AP axis (a line connecting the center of the tibial PCL insertion and the medial border of the patella tendon). We defined the angle of rotating fixation as that between the component rotational axis, in cases in which the bone coverage was maximized, and the tibial AP axis.Results: The simulated angle of rotating fixation between the component rotational axis and the tibial AP axis averaged 4.5°±4.2° (range, -5.1° to 16.2°). The average angle in K-L grade 4 was 4.9°±3.5°, significantly larger than the 3.5°±2.8° angle found in K-L grade 3 (p=0.04).Conclusion: In most cases, the tibial components were fixed for external rotation relative to the tibial AP axis (138 knees, 89.0%). However, the variation among cases was not negligible, and the angle varied widely in the range -5.1° to 16.2°. Furthermore, we found a significant correlation between the angle of rotational fixation and the radiographic grade of osteoarthritis. In the present situation in which a consensus has not been established about the rotational position of the tibial component, we consider it is useful to use a mobile-type insert with a self-alignment mechanism.
- 日本関節病学会の論文
日本関節病学会 | 論文
- 関節リウマチ患者における手術と機能回復
- 低出力超音波刺激(LIPUS)および線維芽細胞増殖因子(FGF-2)の骨形成促進作用におけるヒアルロン酸(HA)の影響
- 変形性関節症に対するグルコサミン・コンドロイチンの有用性 (第36回[日本関節病]学会寄稿)
- 人工膝関節再置換術の経験--脛骨結節骨切り術の適応と合併症について
- RA頚椎病変に対する上位頚椎後方除圧固定術の治療成績と問題点