家庭用ルームエアコンの使用実態調査:-第1 報:運転率による実測結果の考察-
スポンサーリンク
概要
- 論文の詳細を見る
It is important to evaluate the annual performance factor (APF) of room air conditioners (RACs) in accordance with their actual usage in residential sectors. In this study, actual RAC usage was monitored for 100 families over a year by equipping each air conditioner with an electric power meter and a data logger. We monitored 25 families living in detached houses in the Shinetsu area (a cold area), 25 families in the west Kanto area, 25 families in the east Kanto area, and 25 families living in apartments in the east Kanto area. After analyzing the obtained data, two types of operating ratios were introduced—an outdoor-temperature-associated operating ratio (TOR) and an hour-associated operating ratio (HOR). It was found that there is essentially little difference in the TOR and the HOR among the monitored sections or the monitored months in the same season from the standpoint of the sectional or monthly average. We also performed a simple questionnaire survey and compared to the measured data.