気相域におけるフロン系冷媒R23の定圧比熱の測定および状態式の作成
スポンサーリンク
概要
- 論文の詳細を見る
The isobaric specific heat capacity of Refrigerant 23 (CHF3) has been measured by the flow calorimeter. Forty-five measurements were obtained in the gaseous region for temperatures 253 to 383 K and for pressures 0.5 to 3.0 MPa including the region near the saturation line. The sample purity used was 99.99 wt%. The uncertainty of the measurements was estimated to be less than l.5%. Based on the present results in addition to the isobaric specific heat capacity at the ideal gas state, the second virial coefficients and the available PVT data, an equation of state has been formulated as a function of pressure and temperature for the region of the present study. The equation of state expressed by the form of Gibbs free energy reproduces the present results with an average deviation of l.0% and most of the available PVT data within a deviation of ±1%.