ボルト締め付け後に溶接した併用継手のすべり挙動
スポンサーリンク
概要
- 論文の詳細を見る
At hybrid joints of steel girders using bolted and welded joints, it is necessary to implement erection pieces as restrainers of welded joints and to remove them after welding. To enable the connection without the erection pieces, we proposed a new connection method of hybrid joints, in which we use the bolted connections of longitudinal ribs as the restrainers by tightening the bolts before welding. To establish a procedure of the method, we carried out trial execution tests of hybrid joints. As a result, it was clarified that the bolted joints slipped at the time of untightening the bolts, while they did not slip at the welding stage. After the slip, the damage of the friction surfaces was localized to small regions around the remaining bolts.
- 社団法人 日本鋼構造協会の論文
社団法人 日本鋼構造協会 | 論文
- Influence of Thickness of Adherends on Strengthening of Steel Plate with Carbon Fiber Strips
- タイトル無し
- Effect of Chemical Compositions on the HAZ Toughness and Its Formulation under Simulated Column-Beam Connection Welding of Structural Steel for Building
- Newly Proposed HAZ Toughness Evaluation Method of Structural Steel for Building and The Result of Evaluation by Its Application