エクセルギー概念に基づくコージェネレーションシステムの総合効率評価
スポンサーリンク
概要
- 論文の詳細を見る
We have introduced "heat factor" for the evaluation of the total energy efficiency of cogeneration system in Japan. According to our analysis based on exergy basis, the "heat factor" for Japan is calculated to be 0.24 - 0.28, which is much smaller than the factor for US and Europe, which are 0.5 or higher. This result implicates the difficulty of the use of thermal output of cogeneration in Japan, which has little heat demand compared to the US and Europe. By comparing the adjusted total efficiency of cogeneration with the grid power plant (all average, fossil fuel average, state of art LNG combined cycle), we found that it was inappropriate to regard cogeneration as highly efficient just by the simple total efficiency. The adjusted total efficiency was calculated to be nearly equal or a little higher than the average fossil fired power plant depending on the type of demand, and much smaller than the state of art LNG combined cycle for all demand assumed in our study.
- 一般社団法人 日本エネルギー学会の論文
一般社団法人 日本エネルギー学会 | 論文
- Modifying Optical Texture of the Coke from Miike Coal
- Development of Petrochemical Industry with the Background of Iron Manufacturing Industry
- タイトル無し
- Study on Development of Waste Oil Combustion Burner for Energy Saving and Low-Pollution (II): Combustion of Waste Oil and Exhaust Emission Characteristics by Internal Mixing Twin-Fluid Atomizer:Combustion of Waste Oil and Exhaust Emission Characteristics
- Study on Development of Waste Oil Combustion Burner for Energy Saving and Low-Pollution (I): Atomization of High-Viscous Liquid Jet by Internal Mixing Twin-Fluid Atomizer:Atomization of High-Viscous Liquid Jet by Internal Mixing Twin-Fluid Atomizer