異なる二つの磁界強度を用いた漏洩磁束式熱延介在物計の開発
スポンサーリンク
概要
- 論文の詳細を見る
Recently, steel can manufacturing requires higher quality steel because otherwise minute non-metal inclusions in thin sheets could cause cracks and result in a burst during the pressurization after the pressing process. Quality testing is already incorporated during the final process in steel plants, but if there was another inspection in an earlier step, at the hot strip mill for example, then the mass manufacture of non-conforming products could be avoided and the maintenance of quality control would be more efficient. Magnetic Flux Leakage Testing (MFLT) has been developed using different magnetizing, in order to detect inclusion defects in hot-rolled steel plates. In the analysis of the noise factors in MFLT, the signals generated from the scale layer on a steel surface were found to be dominant. A different magnetizing force method is used to decrease this overpowering noise level in MFLT. In this paper, it is confirmed that inclusions, larger than 160μm in diameter and less than 0.45mm in depth, can be detected.
- 一般社団法人 日本非破壊検査協会の論文
一般社団法人 日本非破壊検査協会 | 論文
- フーリエ級数係数を用いたパッシブ赤外線サーモグラフィによるコンクリートのはく離深さ評価
- 複数探触子を用いたTOFD法によるきずの位置と寸法の同定法
- 厚肉材に渦電流探傷法を適用するための新しい励磁手法の提唱
- 鋼板厚さ測定におけるパルス渦電流試験の解析と実験からの検討
- ログアンプとリニアアンプの併用による超音波探傷試験