Stability Inspection Method for Existing Retaining Walls
スポンサーリンク
概要
- 論文の詳細を見る
Visual inspection methods are currently used on existing retaining structures. Consequently it is difficult to evaluate a structural health of the retaining walls quantitatively. In this study, a series of model tests on retaining walls were carried out to develop an inspection method for quantitatively evaluating existing railway retaining walls. It has been found from the series of model tests that vibration tests are an effective means to determine the vibration characteristics of retaining walls, which reflect their structural health. Test results indicated that small scale vibration tests could be applied to evaluation the structural health of existing retaining structures.
- 公益社団法人 鉄道総合技術研究所の論文
公益社団法人 鉄道総合技術研究所 | 論文
- Measurement of the Contact Force of the Pantograph by Image Processing Technology
- Simulation of Passenger Behavior on Board a Commuter Train in the Event of a Level Crossing Accident
- Predicting Concrete Deterioration due to Chloride Corrosion of Reinforcing Bars
- Neutral Point Bias Control Method for Large Capacity Inverter.
- Totally Enclosed Permanent Magnet Synchronous Motor for Commuter Trains