フラックスポンプによる600MHz NMRマグネットのドリフト補償
スポンサーリンク
概要
- 論文の詳細を見る
Although high-Tc superconductors (HTS) are very promising for high-field generation over 25 T, it is difficult to apply them to NMR magnets because of their low index values and the difficulty caused by superconducting joints. It appears that the present properties of HTS cause poor magnetic-field stability in persistent-mode operation. We applied drift compensation based on flux-pump technology to a 600 MHz NMR magnet that had a poor magnetic-field stability of about -0.7 ppm/h. The drift compensation unit consisted of nested inner (secondary) and outer (primary) coils. The inner coil was connected in series to the main coil circuits, and the outer coil was connected to the auxiliary power supply to sweep the output current very slowly. While the current of the outer coil was changed at an adequate sweep rate by the power supply, a current was induced in the inner coil by inductive coupling. The induced current canceled out the decay of the main coil current that caused by the poor drift of the magnet.
- 公益社団法人 低温工学・超電導学会 (旧 社団法人 低温工学協会)の論文
公益社団法人 低温工学・超電導学会 (旧 社団法人 低温工学協会) | 論文
- Test Results of the SMES Model Coil. Cool-down and Thermal Characteristics.:Cool-down and Thermal Characteristics
- Crystal Growth of Y Based Superconductors on Solidification Processing.
- Refrigeration of pressurized He II using a 3He circulation system. (II). Behavior of the system during the initial cooling and after a pulsed heat generation.:Behavior of the System during the Initial Cooling and after a Pulsed Heat Generation
- Quench simulation analysis of a superconducting coil. II. Simulation.:II. Simulation
- タイトル無し