Environmental and Biological Monitoring in a Lead Acid Battery Manufacturing Unit in India
スポンサーリンク
概要
- 論文の詳細を見る
An environmental and biological monitoring of a lead acid battery manufacturing unit was carried out to measure the respirable particulate matter, lead content in working atmosphere and blood lead levels of workers employed in different sections. The results showed high mean air lead concentration in buffing (1444.45 μg/m3), plate cutting (430.14 μg/m3) and pasting (277.48 μg/m3) sections. The mean blood lead levels of employees in these sections were also higher than the values prescribed by ACGIH.
- 社団法人 日本産業衛生学会の論文
社団法人 日本産業衛生学会 | 論文
- Digital blood pressure measurement after local cooling in vibration syndrome.
- Epidemiologic and preventive studies of rubella in female office workers.
- Determination of protoporphyrins in blood using HPLC. Standardization of protoporphyrins and interlaboratory comparison of analyses.:Standardization of Protoporphyrins and Interlaboratory Comparison of Analyses
- A Medical Record System of Chronic Illnesses among Clerical Workers
- The Ideal and the Reality of Environmental Health